Important 
 

This product has been designed not to cause any risks for the maintenance personnel installing the 
appliance nor to the environment. It is important to observe the hereby provided instructions during 
installation and maintenance works. 
All maintenance procedures that require maintenance operations inside the appliance are to be 
performed by the qualified personnel. The appliance contains pressurised cooling gases, hot 
surfaces, moving components (e.g. fans) and various electrical components. 

Always disconnect the power supply before attempting any maintenance operations. 
Make sure the appliance has been provided with and connected to power supply specified on 
the data plate. 
Chiller Oy assumes no legal responsibility for any damages resulting from installation or 
maintenance. 

 

 
1. Transport and Storage 
 

The appliance is shipped on a pallet. Use auxiliary machinery for transportation. Do not remove the 
protective packaging before you begin with the installation procedures. Make sure the delivery 
corresponds to your order. Always store the appliance in a dry and preferably warm room. 
Make sure the delivery contains all accessories indicated in the documents. Any shipping damages 
on the appliance are to be reported to the shipping company within 24 hours from the delivery of 
the appliance. Shipping damages must always be recorded on the freight bill. Chiller Oy guarantees 
the dispatch of a faultless appliance from the plant. 
 
 

2. Warranty Terms 
 

Chiller Oy warranties the appliance for 12 months from the date of commissioning or for 18 months 
from the date of delivery, whichever occurs first. The warranty is valid provided that no 
modifications have been performed on the appliance without the manufacturer’s written consent. 
Warranty treatment presupposes advising the manufacturer of the full type and full serial number of 
the appliance. 
 
 

3. Safety 
 

The cooling appliance produced by Chiller Oy is designed and manufactured in compliance with the 
applicable legislation. Please read these instructions carefully before taking any measures. Always 
employ qualified installation personnel and observe applicable local laws. Should the laws conflict 
with the connections made and instructions given by Chiller Oy, observe the established law but 
provide your measures with an approval from Chiller Oy. 

Summary of Contents for IT 500 Series

Page 1: ...ns Operating Instructions Maintenance Instructions Read this manual carefully before installing and operating the appliance Chiller Oy assumes no legal responsibility for any damages resulting from in...

Page 2: ...of the appliance 7 Setting values of the sensors and safety devices 8 Installation of the appliance 9 Connecting the appliance to the power supply 10 Activating the appliance 11 Connection data of the...

Page 3: ...pliance in a dry and preferably warm room Make sure the delivery contains all accessories indicated in the documents Any shipping damages on the appliance are to be reported to the shipping company wi...

Page 4: ...ir EU4 EU4 Cooling agent standard supply R407C R407C Length L mm 1 620 1 620 Width B mm 800 800 Height H mm 450 450 Grille width BC 900 900 Grille height HC 550 550 Installation hole dimensions B H mm...

Page 5: ...awings A ELECTRICAL BOARD F CONDENSER FAN B SERVICE DOOR FOR THE FAN G SERVICE DOOR FOR THE CONDENSER C SERVICE DOOR FOR THE COMPRESSOR H EXHAUST AIR GRILLE D FREE COOLING WITH INTAKE AIR I FREE COOLI...

Page 6: ...axle Outside temperature exceeding the setting value of the sensor TE3 the fan P1 is not allowed to operate When the temperature in the intake air duct falls below the setting value of sensor TE2 the...

Page 7: ...en a breakdown occurs the relay D1 deactivates the compressor When the indoor temperature exceeds its setting value the free cooling fan P1 is activated and the damper controlling the free cooling is...

Page 8: ...8 Sensor TE3 Fan P1 Fan P2 Fan P3 Motorized damper M...

Page 9: ...9 High pressure switch Compressor Low pressure switch Grille...

Page 10: ...10 7 Setting Values of the Sensors and Safety Devices Appliance Setting value C TE1 25 TE2 12 TE3 18 Appliance Setting value bar LPS 2 3 5 HPS 17 5 24 LPS low pressure switch HPS high pressure switch...

Page 11: ...nstall the appliance above electronic devices or furniture as condense water may accidentally drip from the appliance Make sure the condense pipe allows the water a free flow out of the appliance The...

Page 12: ...threat fasten the l formed sheet metal strips between the appliance and the wall The metal sheets are fastened with 7 mm self tapping screws Supporting of the appliance requires special attention in c...

Page 13: ...13 Fastening with a locking nut A NUT B WASHER C TWIN NUT...

Page 14: ...installation perform the following checks before starting the appliance The appliance has been installed in horizontal position on the proper point of installation The appliance is provided with the...

Page 15: ...he grille and replace it with a new one Wash the old filter in order to get an exchange filter There is an intake air filter at the end of the appliance Remove the filter and replace it with a new one...

Page 16: ...ressor 230 1 50 1 34 6 6 Evaporator fan 230 1 50 0 043 0 2 Condenser fan 230 1 50 0 35 2 8 Free cooling fan 230 1 50 0 09 0 9 IT560 Component Voltage Connection capacity kW Operating current A Compres...

Page 17: ...The control of the condensation pressure does not function Check the control of the condensation pressure The fan of the condenser has stopped Detect the cause of stopping The high pressure switch is...

Page 18: ...04300 Tuusula Finland Declares under its sole responsibility that the construction of the units IT540 IT560 To which this declaration relates is in conformity with the following directives 98 37 EEC...

Page 19: ...fan 1 CH200F Freezing protection board 1 CH300I Control board 1 MOT100I Damper motor 1 FLR001F Evaporator filter 1 FLR100I Free cooling horizontal filter 1 FLR200F Free cooling bag filter 1 GRL003F I...

Page 20: ...0F Freezing protection board 1 CH300I Control board 1 MOT100I Damper motor 1 FLR001F Evaporator filter 1 FLR100I Free cooling horizontal filter 1 FLR200F Free cooling bag filter 1 GRL003F Intake grill...

Page 21: ...ntre of the fan and pull the fan straight downwards Be careful as the fan may be tightly fixed Loosen the screws in the corners of the motor stand The motor is fastened by the rear side of the motor s...

Reviews: