1.

 

FOR YOUR SAFETY 

2.

 

LOCATION REQUIREMENTS 

3.

 

INSTALLATION PROCEDURES 

4.

 

PRESSURE LIMITER 

(optional)

 

5.

 

CLEANING & SANITIZING 

6.

 

STORAGE 

7.

 

QUICK CONNECTOR FITTINGS 

8.

 

PRIMARY COMPONENTS DIAGRAM 

9.

 

ADJUSTING THERMOSTAT 

10.

 

SPECIFICATIONS 

11.

 

TROUBLESHOOTING  GUIDE 

12.

 

WARRANTY & SERVICE 

 

 

 

 

 

Chiller Daddy LLC 

Huntington, IN  46750 USA 

www.ChillerDaddy.com

 

 

 
 

 For best use of your Chiller we advise reading these instructions carefully as they contain important information. 

 Keep this manual for future reference.  Ver. 102 

 Chiller Daddy LLC reserves the right to change specifications and design without notice. 

▲ 

CHILLER DADDY® is the Registered Trademark of CHILLER DADDY LLC 

Summary of Contents for CHL-501

Page 1: ...Y COMPONENTS DIAGRAM 9 ADJUSTING THERMOSTAT 10 SPECIFICATIONS 11 TROUBLESHOOTING GUIDE 12 WARRANTY SERVICE ChillerDaddyLLC Huntington IN 46750USA www ChillerDaddy com For best use of your Chiller we a...

Page 2: ...caused the drain plug to loosen 2 LOCATION REQUIREMENTS This Chiller is intended to be installed underneath a conventional kitchen sink in a cabinet not less than 36 914mm wide inside dimension Chille...

Page 3: ...l use 30 insulated OD faucet connection poly tube is included This insulated tube not only helps to keep the water colder but also prevents condensation from forming on the tube and running down onto...

Page 4: ...ke sure to start with a clean tube without any foreign material free of score marks and scratches Use a utility knife with a fresh blade or Tube Cutter Do NOT use a hacksaw Step 2 Inserting the Tube W...

Page 5: ...ng 8 PRIMARYCOMPONENTSDIAGRAM 9 ADJUSTINGTHERMOSTAT The thermostat is factory preset and requires no adjustment other than for abnormal requirements If needed the water temperature can be adjusted by...

Page 6: ...Power 110 Volts 60Hz 3 Prong Grounded Cord Attached 1 8A 140W Motor Compressor Thermally Protected Certifications Conforms to UL Standard 399 Certified to CSA Standard C22 2 s 60335 2 24 60335 1 Refri...

Page 7: ...the thermostat as necessary The ambient temperature is high It is normal for the Chiller to run continuously at high ambient temperatures C Water is not cold but the Chiller compressor runs continuous...

Page 8: ...erial number Please retain your receipt or invoice as proof of purchase date and location This warranty applies only in the country in which the unit was originally sold This Limited Warranty does not...