1.4 

運転

 

Operation 

 

運転中に移動させないで下さい。

 

Do not move it during the operation. 

 

停電した時には、電源を切って下さい。復旧時に、けが・装置破損の原因になります。

 

Turn OFF the power when an instantaneous power interruption occurs. 
Otherwise, injury or product damage may be caused when the product recovers. 

 

フィルタを取り外したり、目詰まりや破損した状態で運転すると、

 

ブロア内への異物が混入して、故障の原因となります。  正しくフィルタを取り付けてご使用ください。

 

Operation  without  filter  or  with  a  clogged  and  damaged  filter  may  cause  trouble,  because  foreign 
substances enter the blower. Install the filter properly before operating the machine. 

1.5 

修理・分解・改造

   

Repair, disassembly and modification

 

 

本体を分解・改造しないで下さい。感電・けがの原因になります。内部の点検や修理はお買い上げになった販売店に
連絡して下さい。

 

Do not disassemble or modify the machine. 
Disassembly and modification may cause an electrical shock and injury. 
Contact your dealer for internal inspection and repair. 
 

1.6 

廃棄

 

 

Disposal

 

 

産業廃棄物として適切に処分してください。

 

Dispose of the product properly as industrial waste. 

2

 

製品到着時の確認

  Confirmation and Preparation at Arrival 

 

開梱されましたら、各部の不足部品がないかご確認下さい。

 

万一、運送途中での破損・部品不足などがございましたら、すぐにご連絡下さい。

 

After unpacking, make sure that all parts are provided. 

Contact our company immediately if parts are damaged during transportation or not provided.

 

 

本体

 

Main Body

 

製品ネームプレートは本体に貼っていますので、ご確認下さい

 

Confirm the nameplate.

 

 

フィルタ(本体にセットされています)

 

Filter

set in the machine

 

  1

次フィルタ

Primary filter

・・・・

 

・・・・・

 

FB-25, FB-30, FB-700-22

 

 

  2

次フィルタ

Secondary filter

・・・・・・・

 

CHF-2525-50

CCW-2525-50

, CHF-3030-50, CHF-3535-70 

 

排気フィルタ

Exhaust filter

・・・・・・・・・

 

CHF-2525-50, CHF-3030-50, CHF-3535-70 

 

排気フィルタ

Exhaust filter(V1) 

・・・・

 

HEP-2525-50, HEP-3030-69, HEP-3535-69 

 

 

電源ケーブル(付属)とリモートケーブル(別売)

 

 

Power cable(standard accessory) and Remote cable(option) 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

電源ケーブル

Power cable

 

(3m)  ×1 

※  ケーブルは地域によって異なります。 
※  The cable is different in each region. 

 

リモートケーブル(別売)    MT-173-8 

Remote cable(option)

(3m)  ×1 

抜け防止の設計となっております。くぼみを下にし、しっかりと差し込んで
下さい。

(ピンの位置を必ず確認してください) 

The remote cable is so designed as to be prevented from falling off. 
Insert it securely with its dent facing downward. 
(Make sure to confirm pin positions.) 

100-115V

国内

 

Japan

 

本体差し込みプラグ

 

/

コンセントプラグ有り

 

200V 

国内

Japan

 

本体差し込みプラグ

 

/

コンセントプラグ付無し

 

 

220-240V 

海外

Other than Japan

 

本体差し込みプラグ

 

/

コンセントプラグ有り

 

 

Summary of Contents for CKU-080AT2-HC-CE

Page 1: ...that you can use it safely for a long time and enjoy its full performance Symbols used in this manual WARNING This symbol indicates actions that should not be performed in any case or actions that may...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...irmation before operation 10 4 5 Operation procedure 11 4 6 C CC 11 4 7 E EE 12 4 8 12 5 Remote Cable Sold Separately 13 5 1 Electrical circuit diagram 13 5 2 Color and signal of each wire 14 6 Mainte...

Page 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Page 5: ...of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our company immediately if parts are damaged during...

Page 6: ...e of main body AT AT Panel operation panel Suction port Desorption type MAIN POWER switch BOX Fuse Box Remote connector CKU 450AT2 HC CE V1 MAIN POWER switch Differential pressure sensing gauge Consol...

Page 7: ...ine dust and fumes Secondary filter Protecting the circuit and the electrical parts Exhaust filter Exhaust treatment 3 3 Desorption flange CKU 080AT2 CKU 240AT2 CKU 080AT2 HC 50 38 CKU 240AT2 HC 65 50...

Page 8: ...anel Operating the product with a different power supply may cause a failure Never adopt star burst connection that may cause voltage drop If voltage drop occurs longer time is required for startup ON...

Page 9: ...7 3 3 0 9 99KPa E EE 1 7 0 2 Pa 0 2 Pa The pressure representation when operation stops changes within the range from 0 2 to 0 2 Because there is a change in the atmospheric pressure and the temperat...

Page 10: ...mp of AT panel lights AT ON Press the ON switch AT Panel to start operation The operation indicator lamp lights Confirm that abnormal sounds such as metallic sounds are not generated Confirm that the...

Page 11: ...ator lamp lights Starts the dust collector AT ON Press the ON switch to start the operation Confirm again that abnormal sounds are not generated and confirm that the suction hose offers proper suction...

Page 12: ...Copyright CHIKO AIRTEC CO LTD 2009 12 4 7 E EE E EE 19 7 11 4 5 E EE 4 8 2 050 30 70 50 40 30 70 60 30 2 2 2 1 30...

Page 13: ...ND 7 GND Ability level change input signal 5 Remote Cable Sold Separately 5 1 Electrical circuit diagram Remote operation switch ON Shifting to remote mode Remote control is possible in the ON and the...

Page 14: ...ion switching signal Short circuits the wires 4 and 8 to start remote operation The AT panel is disabled while the wires 4 and 8 are short circuited Yellow 0 5 Yellow white Black White Operation press...

Page 15: ...signal of each wire ON OFF 5 3 Do not short circuit the wires 4 and 8 each other when transferring signals by turning ON and OFF the dust collector from the main body Transfer required output signals...

Page 16: ...ake sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting inspection Using a worn or damaged filter will release sucked du...

Page 17: ...ary filter from the filter case The paper packing of the primary filter is inserted into the cylindrical pipe of the filter case Pull the paper packing toward you to remove the primary filter 2 Open t...

Page 18: ...ody Once day Are no abnormal vibrations or sounds generated Is the installation level correct Filter installation status Once month Are the filters installed securely Filter clogged status Suction for...

Page 19: ...he motor is not overheated by clogged filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status S...

Page 20: ...Copyright CHIKO AIRTEC CO LTD 2009 20 8 Indication of DANGER Labels Electrical Circuit Diagram 8 1 CKU 080AT2 HC T CE MODEL...

Page 21: ...Copyright CHIKO AIRTEC CO LTD 2009 21 8 2 CKU 240AT2 HC T CE MODEL...

Page 22: ...Copyright CHIKO AIRTEC CO LTD 2009 22 8 3 CKU 450AT2 HC T CE MODEL...

Page 23: ...2 50 60 7 0 2 9 58 73 30 5 CKU 450AT2 HC T 450 200V Single phase 4 2 50 60 7 0 2 9 58 73 30 5 CKU 450AT2 HC CE 450 220 240V Single phase 4 2 50 60 7 0 2 9 58 73 30 5 1 dB Note The Noise column indica...

Page 24: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: