![Chigo CCA-18CR1 Technical Manual Download Page 172](http://html1.mh-extra.com/html/chigo/cca-18cr1/cca-18cr1_technical-manual_2601239172.webp)
R410A50Hz Universal Outdoor Series Technical ManualController
169
GD Chigo Heating & Ventilation Equipment Co., Ltd.
③
Keep pressing will continuously change the temperature.
(
5
)
Up and down swinging (
External pendulum wind
)
①
Pressing this key in the dehumidification mode, the external pendulum wind is forced to close.
②
Pressing this key in the other modes, the external pendulum switches by "swing, fixed wind, swing"
circularly.
(
6
)
Left and right swinging (
Internal pendulum wind
)
①
Pressing this key in the dehumidification mode, the internal pendulum wind stays unchanged
according to the state before switching.
②
Pressing this key in the other modes, the internal pendulum switches by "swing, stop, swing"
circularly.
(
7
)
“FAN -”
①
When the first power on, the remote controller is set to the automatic wind speed by default. In
dehumidification mode, the wind speed is fixed to low wind and is not adjustable. By pressing the
wind speed key, there is no response to the remote controller.
②
Pressing this key in the other modes, the wind speed switches by "automatic wind speed, high
speed, middle speed, low speed, automatic wind speed " circularly.
(
8
)
“FAN +”
①
When the first power on, the remote controller is set to the automatic wind speed by default. In
dehumidification mode, the wind speed is fixed to low wind and is not adjustable. By pressing the
wind speed key, there is no response to the remote controller.
②
Pressing this key in the other modes, the wind speed switches by "automatic wind speed, low
speed, middle speed, high speed, automatic wind speed " circularly.
(
9
)
Timer
①
Under the shutdown state, press this key to set the opening time, range from 1 hour to 24 hour.
②
Under the boot state, press this key to set the shutdown time, range from 1 hour to 24 hour.
③
The timing time is according to the cycle of "1h, 2h,
……
, 23h, 24h, cancel, 1h".
④
Exit timing adjustment after 3 seconds without key pressing.
(
10
)
TURBO
①
Extension code remote controller has the effect. The remote controller is no TURBO by default,
and the TURBO key will not work in automatic mode, dehumidification mode and fan mode.
②
Pressing this key in the cooling or heating mode, the TURBO mode switches between opening and