RSE
Installation Instructions
8
1d
Ø 6.3mm
(Ø 1/4”)
64mm
(2-1/2”)
Solid Concrete Installation
NOTE:
CPA adapter must be removed prior to
installing RSE to concrete. See Section 1a for
details.
1.
Determine mounting location.
WARNING:
The RSE is designed to be mounted to
a concrete ceiling with a minimum thickness of 8" and
a maximum drywall covering of 5/8".
WARNING:
IMPROPER INSTALLATION CAN
RESULT IN SERIOUS PERSONAL INJURY OR
DAMAGE TO EQUIPMENT! Structural members
MUST
be capable of supporting five times the
combined weight of all equipment being mounted.
2.
Using the RSE as a guide, mark four mounting hole
locations on ceiling using a pencil or similar tool.
3.
Drill four 1/4" (6.3mm) diameter pilot holes to a
depth of 2-1/2" (64mm) deep.
4.
Align four mounting holes in RSE with four pilot
holes.
IMPORTANT ! :
Make sure mount is properly
oriented towards target before securing to
structure.
WARNING:
Anchors (not provided) must be
installed into structurally sound solid concrete.
Installation into hollow concrete block, mortar, or
concrete that exhibits cracking, spalling, or other
defects may result in failure of anchor and serious
personal injury or damage to equipment.
5.
Install four 3/8" x 2-1/4" concrete anchors (not
included) by inserting into pilot holes and pounding
in until flush with mounting surface.
6.
Secure RSE to structure using four #10 flat washers
and four #10 x 3" Phillips head wood screws. (not
included)
3
X4
X4
1
2
(A)
5
X4
6
X (4)