Page 1: ...RIGOL Installation Guide RM DM 3 Rackmount Kit DM3000 Series Digital Multimeter Apr 2011 RIGOL Technologies Inc ...

Page 2: ...s all previously corresponding material RIGOL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information contained Any part of this document is forbidden to be copied or photocopied or rearranged without prior written approval of RIGOL Product Certification RIGOL guarantees this product ...

Page 3: ...actices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury or hazard that may immediately happen WARNING indicates a potential injury or hazard that may happen CAUTION indicates that a potential damage to the instrument or other property might occur Symbols on the Product These symbols may appear on th...

Page 4: ... Part Number Description 1 1 Front Panel 1 RM DM 3 01 1 2 Support Board 1 RM DM 3 02 1 3 Left Plate 1 RM DM 3 03 1 4 Right Plate 1 RM DM 3 04 1 5 Fixed Finger 2 RM DM 3 05 2 1 M4 Screw 16 RM SCREW 01 M4 6 Phil Slot Pan Head Machine Screw Nail 2 2 M6 Screw 4 RM SCREW 02 M6 16 Phil Slot Pan Head Machine Screw Nail 2 3 M6 Nut 4 RM SCREW 03 M6 5 Square Machine Female Screw Contain Lock Blade Figure 1 ...

Page 5: ...equirements must be fulfilled by the machine cabinet in which the instrument is mounted 1 The machine cabinet should be a standard 19 inch 2 At least 3U spaces 133 5mm have to be provided by machine cabinet 3 The depth inside the machine cabinet should not be less than 400mm Figure 3 Dimension of Instrument with Rack Adapter Installed ...

Page 6: ...Installation Tools List NO Name Description 1 Phillips screwdriver PH2 Phillips screwdriver CAUTION Only authorized personnel can perform the installation improper operation may cause damage to the instrument or incorrect installation Installation Procedures 1 Remove handle from instrument grip the handle in both sides and pull it outward Then push the unit upward to release it from the instrument...

Page 7: ...ight and left plate at the openings on support board and insert selectively then fix them using eight M4 bolts Figure 5 Installation of Left and Right Plate 3 Place the instrument aim the parallels of instrument at the corresponding openings and then put it onto the support board Figure 6 Place the Instrument ...

Page 8: ...ten or fit the instrument tightly into the support board using two fixed fingers in connection with four M4 bolts Figure 7 Fix the Instrument 5 Mount front panel aim the opening of front panel at the front of instrument and fix them using four M4 bolts Figure 8 Mount Front Panel ...

Page 9: ... with instrument fixed onto a standard 19 inch machine cabinet respectively using 4 M6 bolts and square nuts Figure 9 Loading into Machine Cabinet Notice The rack holds a height of 3U and the holes those in compliance with the arrow direction are the mounting holes for rack Figure 10 Holes for Rack ...