8
2-6. Stud Mode Cable Connection
CAPACITOR DISCHARGE STUD WELDING
STUD WELDING TORCH
Welding torch cable
Control cable
Earth (Ground) 2 cables
Input cable -
Connect to the
back of machine
AC 110V/230V/380V 15A
(1) Cable connections (Refer to the diagram above).
1. The torch cable and earth (ground) cables use Euro type quick connectors. Push the plug into the socket,
torch cable to “GUN (-)” socket, earth (ground) cable to “STUD EARTH (GROUND) (+)” socket, and turn right for
secure connection.
2. The input cable and control cable connectors use screws to secure connections.
3. The earth (ground) cables must be clamped to the base metal.
4. All cables should be kept straight. If the cables are twisted it will interfere with stud welding.
(2) Negative connection----apply to zinc coated steel, steel plate, plate brass, and titanium stud screws.
The earth (ground) cable connects to the “GUN (-)” socket, The torch cable connects to the “STUD EARTH
(GROUND) (+)” socket.
The torch and earth (ground) cables exchange connections.