Installation Instructions
MCD Series
5
INSTALLATION
WARNING:
FAILURE TO PROVIDE ADEQUATE
STRUCTURAL STRENGTH FOR THIS COMPONENT CAN
RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE
TO EQUIPMENT! It is the installer’s responsibility to make
sure the structure to which this component is attached can
support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
IMPORTANT ! :
These installation instructions assume
that a 1-1/2" NPT or NPSM (Schedule 40, 0.154"
minimum thickness aluminum - ASTM B221) pipe (not
included) has been properly installed and is in place.
Attaching Mount to NPT Pipe
CAUTION:
Watch for pinch points. Do not place fingers
between moveable parts.
1.
Thread the MCD mount (A) onto the existing 1-1/2" NPT or
NPSM pipe (not included) until tight. (See Figure 1)
2.
Install and tighten the 5/16-18 x 3/8" set screw (B) using the
5/32" hex head wrench (C). (See Figure 1)
Figure 1
Attaching Interface Bracket to Display
1.
Attach interface bracket to display following instructions
included with interface bracket kit.
Attaching Displays to Mount
1.
While supporting both sides of display, align four mounting
buttons on display or interface bracket with four mounting
holes in mount. (See Figures 2, 3 and 4)
Figure 2
WARNING:
DISPLAY MAY WEIGH IN EXCESS OF 40
LBS! Always use two people and proper lifting techniques
when installing or positioning display on mount.
2.
Lower display into place listening for audible "click" to
ensure recessed area of mounting buttons are properly
seated in lower area of mounting holes and ClickConnect
mechanism has engaged. (See Fig. 2, 3 and 4)
Figure 3
WARNING:
IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Ensure mounting
buttons are completely engaged in mounting holes.
Holes are provided in the faceplate for use with a padlock or
similar locking device, if desired. In addition, the pin and nut may
be removed from the upper holes and moved to the lower holes
for use as a more permanent locking device. (See Figure 4).
(A)
NPT
Pipe
2
1
(B) x 1
1
(A)
Display
(A)
Back
of Display
Interface Bracket
(will vary in
appearance)