background image

MAC501

Installation Instructions

2

DISCLAIMER

Milestone AV Technologies, and its affiliated corporations and
subsidiaries (collectively, "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.

Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.

 IMPORTANT WARNINGS AND

CAUTIONS!

WARNING:

A WARNING alerts you to the possibility of

serious injury or death if you do not follow the instructions.

CAUTION:

A CAUTION alerts you to the possibility of

damage or destruction of equipment if you do not follow the
corresponding instructions.

WARNING:

Failure to read, thoroughly understand, and

follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty!  It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.

CAUTION:

This equipment must be installed and

assembled by qualified service personnel in accordance with
local building codes.

WARNING:

Failure to provide adequate structural strength

for this accessory can result in serious personal injury or
damage to equipment!  It is the installer’s responsibility to
make sure the structure to which this accessory is attached
can support the combined weight of the box and all
equipment not to exceed 75 lbs (34.02 kg).

NOTES:

SUITABLE FOR USE IN OTHER ENVIRONMENTAL AIR SPACE IN ACCORDANCE WITH SECTION 300.22,
(C) OF THE NATIONAL ELECTRICAL CODE.

The maximum specified ambient temperature of the cabinet system is 40° - 120°F (4° - 49°).

Minimum spacings between the accessories and components and the housing for Information Technology
Communication Equipment shall be maintained for safe operation of the equipment when installed in
accordance with the National Electric Code, ANSI/NFPA 70-1999. Refer to communication equipment
manufacturer’s specifications for minimum spacings.

This Cabinet System is for use with ITE or Audio/Video equipment only.

Summary of Contents for MAC501

Page 1: ...ng Instruções de Instalação Istruzioni di installazione Installatie instructies Instructions d installation IN WALL ENCLOSURE Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description MAC501 ...

Page 2: ...d thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided CAUTION This equipment must be installed and assembled by qualified service personnel in accordance with local building codes...

Page 3: ...Bevestiging losdraaien Desserrez les fixations Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren...

Page 4: ...REQUIRED FOR INSTALLATION PARTS 3 16 A 1 B 6 M7 x 40mm C 6 08 x 1 2 D 1 M4 Grounding screw and washer installed at factory Earthing symbol IEC 60418 No 5019 affixed adjacent to grounding terminal Extras if needed for installing electrical box ...

Page 5: ... fasteners WARNING EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surfaces is free of gas water waste or any other plumbing before cutting drilling or installing fasteners 2 Using a stud sensor locate and mark studs 3 Center and level housing between marked studs 4 Using housing as a template draw ...

Page 6: ...ix 3 16 diameter pilot holes in studs at mounting holes 7 Attach the MAC 501 A using six M7 x 40mm Allen head connector screws B into pilot holes using an M4 Allen head drill bit D DANGER IMPROPER WIRING CAN LEAD TO DEATH OR SEVERE PERSONAL INJURY Grounding must be installed by qualified personnel using a UL Recognized No 12AWG Green and Yellow grounding wire connected to grounding lug on mount Fi...

Page 7: ...Installation Instructions MAC501 7 ...

Page 8: ...any www chiefmfg com 06 09 USA International A 8401 Eagle Creek Parkway Savage MN 55378 P 800 582 6480 952 894 6280 F 877 894 6918 952 894 6918 Europe A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA P 86 755 8996 9226 F 86 755 8996 9217 ...

Reviews: