6

Figure 4

2

(K) X 2

(P) X 2

(A) X 2

(Q) X 2

(N) X 2

(T) X 2

1

3

4

(M) X 4

INSTALLATION

WARNING:

FAILURE TO PROVIDE ADEQUATE

STRUCTURAL STRENGTH FOR THIS COMPONENT CAN
RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE
TO EQUIPMENT!  It is the installer’s responsibility to make
sure the structure to which this component is attached can
support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.

Swing Arm Installation

1.

Insert pivot pin (Q) into Y-connector upper bore. (See Figure
4)

2.

Install spacer (N). (See Figure 4)

3.

Insert arm assembly (A) on pivot pin (Q). (See Figure 4)

4.

While holding nut (T) in lower bore of Y-connector, insert 5/
16-18 x 4" button head cap screw (K) through washers (M),
UHMW washer (N), arm assembly (A), spacer (P) and Y-
connector, into nut (T). (See Figure 4)

5.

Loosely install screw (K) using 3/16" hex key (F). (See
Figure 4)

6.

Repeat Steps 1 through 5 for second mount arm assembly
(A).

Display Installation

The mounting holes on the back of the display will be

flush with

the back surface, or

recessed into

 the back.  Refer to the

applicable installation procedure below.

Flush Mount Display Installation

CAUTION:

IMPROPER INSTALLATION CAN LEAD TO

DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Using screws of
improper size may damage your display!  Proper screws will
easily and completely thread into display mounting holes.

CAUTION:

IMPROPER INSTALLATION CAN LEAD TO

DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Inadequate thread
engagement in display may cause display to fall!  Back out
screws ONLY as necessary to allow installation of Centris
bracket!

1.

Ensure Centris cup is able to swivel and tilt easily, yet still be
tight enough to hold display in desired position.  Adjust as
required before proceeding.  See "ADJUSTMENT" for
detail.

2.

Using Phillips screwdriver, carefully install two screws (R3)
into the

upper

 mounting holes on the display.  Thread

screws completely into display, then back out 3 complete
turns. (See Figure 5)

3.

Align two screws (R3) (installed on the back of the display in
the previous step) with the two top teardrop mounting holes
on the Centris cup. (See Figure 5)

Summary of Contents for KWY220

Page 1: ...I N S T A L L A T I O N I N S T R U C T I O N S Dual Height adjustable Wall Mount KWY220...

Page 2: ...damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury...

Page 3: ...l Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche By Hand A mano Von Hand Com a m o A mano Met de hand la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabe a...

Page 4: ...2 J 2 F 1 N 2 Q 2 5 16 18 T 2 500 x 194 x 375 3 16 R1 4 R2 4 R3 4 R4 4 R5 4 M4 X 12mm M4 x 20mm M4 x 30mm 500 x 194 x 750 P 2 spacer L 2 G 1 3 32 cable management cover S 2 10 UHMW pivot pin arm assem...

Page 5: ...nto wood stud Ensure bracket C is vertical then tighten screws L See Figure 1 IMPORTANT Overtightening screws L may cause bracket C to compress into soft wall surface resulting in difficult mount inst...

Page 6: ...the back of the display will be flush with the back surface or recessed into the back Refer to the applicable installation procedure below Flush Mount Display Installation CAUTION IMPROPER INSTALLATI...

Page 7: ...ORTANT All spacers used should be the same length If the recess depths result in multiple spacer lengths then select the longer spacer 5 Place the four spacers R1 or R2 over each mounting hole on the...

Page 8: ...that adequate cable slack exists for movement of display and that cables will not be pinched by installation of cover H or screws G 5 Carefully insert cables in cavity located in lower portion of mou...

Page 9: ...Installation Instructions KWY220 9 Swing Arm Tension Adjustment 1 Using 3 16 hex wrench F loosen or tighten adjustment screw s as necessary See Figure 12 Figure 12...

Page 10: ...KWY220 Installation Instructions 10...

Page 11: ...Installation Instructions KWY220 11...

Page 12: ...5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA P 86 755 8996 9226 F 86 755 899...

Reviews: