background image

6

key 

AV, turn knob AI until the display ALshows the 

abbreviation 

DEL and press the key againAV for 3 more 

seconds.

A current/voltage parameter may be restored  outside 

saving  for both using or changing it. To restore it press 

for 3 seconds key 

AV, display by menas of knob AI the 

number to be restored and show on display 

AL, with 

knob

ANthe abbreviation rcL; now just press for at least 

3 seconds key 

AV.

LED AZ JOB.

Shows that you are inside the saving menu of the saved 

working points.

Selection key AY. 

Gas Test .

When this jey is pressed gas stars flowing; to stop it press 

the key again.

If the second press does not takes place the  gas output 

is interrupted after 30 seconds

Selection key AW.

Wire test.

Allows the wire feed with no current or voltage present. 

When  this  key  is  held  down,  during  the  first  5  seconds 

the wire advances at the speed of 1 meter per minute and 

then the speed increases up to 8 meters per minute.

When this key is released the motor stops immediately.

 5. SERVICE FUNCTIONS.

Press the key 

AE, and hold it down for at least 3 seconds 

to enter the submenu. Turning the knob 

AI  you select the 

function, shown on the display 

AL and turning the knob 

AN  you select the type of operation or the value, shown 

on the display 

AM. To return to the normal display, press 

and release the key 

AE immediately.

1- H2O (Cooling unit, optional).

Turning the knob 

AN you select the type of operation:

OFF = shut off, ON 

C = always on, ON A = automatic 

start-up.

When  the automatic mode is selected  the pump begins 

working immediately at each welding start command and 

stops 3 minutes after the welding is completed.

At each power source start-up a short pump test takes 

places for15 seconds.

If an insufficient presssure is detected the machine goes 

into warning  mode and  H2O flashes on display 

AM.

If th elow pressure condition persists  for more than 30 

seconds, the pump is disactivated and the machine goes 

to error mode (ERR 75).

2- TRG.

Choice between 

2- or 4- stages 3 levels, the selection 

2t and  4t with the selection key AU, without  entering the 

service functions. 

2t  the machine begins welding when the welding torch 

trigger is pressed, and stops when released. 

4t to begin 

welding press and release the welding torch trigger; to 

interrupt, you must press and release it again. 

3L  this 

procedure is active in the synergic processes. Specially 

well suited to weld aluminum.

3 currents are available that can be used in welding by 

means of the welding torch start button. The current and 

the slope values are set as follows:

SC  starting current (Hot Start). With the possibility of 

adjusting from 1 to 200% of the welding current, a value 

adjusted using the knob  

AN.

Slo slope. Possibility of adjusting from 1 to 10 seconds.

Defines the connection time between the first current  

SC 

with the welding current and the second  current with 

the 

 third current CrC ( crater filler current), a value set by 

means of  knob 

AN.

CrC - «Crater  filler»  current.  With  the  possibility  of 

adjusting from 1 to 200% of the welding current, a value 

adjusted using the knob  

AN.

Welding starts at the welding torch button pressure, the 

named pressure will be the starting pressure 

SC.

This current is kept as long as the welding torch button 

is held down; when the welding torch trigger is released  

the first current connects to the welding current, set by 

means of   knob 

AI, and is kept as long as the welding 

torch button is held down. When  the welding torch trigger 

is pressed again the welding current connects to the third 

current   

CrC . and is kept as long as the welding torch 

trigger is held down. When the welding torch trigger is 

released  welding stops.

3- SP (spot-welding).

Off/ON activates and disables the spot function.

The spot welding time  

tSP is set from  0.3 to 5 seconds.

The interval between two spots  

tIN is set from  0,3 to 5 

seconds.

This function is  è blocked when function 

3L is activated.

4- HSA (Automatic Hot Start).

This function is blocked when  function 

3L is activated  and 

works only with the synergic processes. Once the function 

has been enabled using the 

AN knob, the operator may 

adjust the level of the starting current 

SC (Hot Start), with 

the possibility of adjusting from 1 to 200% of the welding 

current, a value adjusted using the knob 

AN .

The  duration 

tHS (default 130%) of this current may also 

be adjusted from 0.1 to 10 seconds.) (default 0,5 sec.).

The switching time 

Slo between the SC  current  and 

the welding current may also be adjusted from 0.1 to 10 

seconds.(default 0.5 seconds).

5- CrA (final crater filler).

This function may be selected by means of  key 

AI and is 

working during  welding 

2t or 4t and  also in combination 

with function HSA, if so requested.

After activating function 

«On» by means of  knob AN

rotate  knob 

AI to display the abbreviations:

Slo = Fitting time between the welding current and the 

crater filling time. Default 0.5 sec.

Range 0.1 – 10 seconds.

CrC  =  crater  filling  time  expressed  as  a  percentage  of 

the welding wire speed. Default 60%. Range from 10  to 

200%.

TCr = duration of the filling  current time. Default 0.5 sec. 

Range 0.1 – 10 seconds.

6- PrF (Pre-gas). 

The adjustment may range from 0 to 3 seconds.

Summary of Contents for Elektron MultiMig 621

Page 1: ...UEL D INSTRUCTIONS POUR POSTE A SOUDER A FIL page 9 E MANUAL DE INSTRUCCIONES PARA SOLDADORA DE HILO pag 17 Spare parts and electrical schematic Pièces détachées et schéma électrique Partes de repuesto y esquema eléctrico Page Sid sel 25 28 15 07 2015 3 300 117 ...

Page 2: ...elded cut Do not work next to welding cutting power source EXPLOSIONS Do not weld in the vicinity of containers under pressure or in the presence of explosive dust gases or fumes All cylinders and pressure regu lators used in welding operations should be handled with care ELECTROMAGNETIC COMPATIBILITY This machine is manufactured in compliance with the in structions contained in the standard IEC 6...

Page 3: ...ent absorbed considering the duty cycle This value usually corresponds to the capacity of the fuse delayed type to be used as a protection for the equipment IP23S Protection rating for the housing S Suitable for use in high risk environments NOTE 1 The machine has also been designed for use in environments with a pollution rating of 1 See IEC 60664 2 This equipment complies with IEC 61000 3 12 pro...

Page 4: ...latters LED AG Hold May not be selected It signals that the values shown on the displays AL and AM normally Amperes and Volts are those used during last welding Activated at the end of each welding session LED AH Voltage In all welding processes it indicates that the display AM shows the re set welding voltage or if in combination with LED AG lit the last measured voltage Knob AI The following val...

Page 5: ...9 Selection key AO Each time this key is pressed the selected process is shown by LED AP AQ AR LED AP Pulsed MIG Shows that the selected process is the synergic MIG Pulsed LED AQ SYNERGIC MIG Shows that the selected process is synergic MIG LED AR CONVENTIONAL MIG Shows that the selected process is conventional MIG Selection key AU Each brief pressure selects 2 stages mode MANUAL and the 4 stages m...

Page 6: ... torch start button The current and the slope values are set as follows SC starting current Hot Start With the possibility of adjusting from 1 to 200 of the welding current a value adjusted using the knob AN Slo slope Possibility of adjusting from 1 to 10 seconds Defines the connection time between the first current SC with the welding current and the second current with the third current CrC crat...

Page 7: ...urn the knob AI until the display shows the the abbreviation tfP This is the duration of the highest wire speed thus the highest current It is expressed as a percentage of the time gained from the Fdp frequency see figure 3 Turn knob AN to adjust the percentage Range between 25 and 75 default 50 E TurnknobAI unitlthedisplayshowstheabbreviationAdP arc length of the highest current Range between 9 9...

Page 8: ...g parameters are set by means of knob AI Synergic MIG Welding LED AQ on Select the PROG number based on the wire diameter to be used the type and quality of the material and the type of gas using the instructions located inside the wire feeder compartment Set the functions in the submenu according to the instructions under paragraph Service functions Adjust the wire speed and the welding voltage u...

Page 9: ...la zone de soudure ou de découpe Ne pas travailler près du générateur EXPLOSIONS Ne pas souder à proximité de récipients sous pression ou en présence de poussières gaz ou vapeurs explosifs Manier avec soin les bouteilles et les détendeurs de pression utilisés dans les opérations de soudure COMPATIBILITE ELECTROMAGNETIQUE Cette machine est construite en conformité aux indica tions contenues dans la...

Page 10: ...rès les normes suivantes IEC 60974 1 IEC 60974 5 IEC 60974 10 Cl A IEC 61000 3 12 voir remarque 2 N Numéro matricule à citer pour toute question concernant le poste à souder 3 f1 f2 Convertisseur statique de fréquence triphasé Transformateur redresseur MIG Indiqué pour la soudure MIG MAG U0 Tension à vide secondaire X Facteur de marche en pour cent Le facteur de marche exprime le pourcentage de 10...

Page 11: ...hes utilisées pour la soudure MIG MAG Doit être utilisé exclusivement avec ce générateur 3 2 DESCRIPTION DES PROTECTIONS 3 2 1 Protection pression liquide de refroidissement Cette protection est obtenue avec un pressostat inséré dans le circuit de refoulement du liquide qui commande un microinterrupteur La pression insuffisante est signalée par le sigleH2O clignotant sur le display AM 3 2 2 Fusibl...

Page 12: ... le VOYANT AG la dernière tension mesurée Bouton AI Les valeurs suivantes sont réglées Courant de soudage A vitesse du fil épaisseur numéro du programme PRG Dans les fonctions de service sélectionne les fonctions TRG SP HSA CrA PrF PoF Acc bb L Dp PPF Ito Fac Dans les programmes MIG synergiques sélectionne une taille et les autres se modifient par conséquent Toutes ces tailles sont affichées sur l...

Page 13: ...aires de valeurs courant tension peuvent être mémorisées Pour effacer un numéro mémorisé il faut appuyer pendant 3 secondes minimum sur la touche AV tourner le bouton AI jusqu afficher sur le display AL le sigle DEL et appuyer de nouveau sur la touche AV pendant 3 secondes encore Il est possible de rappeler un paramètre de courant tension en dehors de la mémorisation pour le modifier aussi bien qu...

Page 14: ...ult 0 5 sec 5 CrA crater filler remplissage du cratère final La fonction peut être sélectionnée avec le bouton AI et elle fonctionne pendant le soudage 2t ou 4t et si on le désire aussi en union avec la fonction HSA Après avoir activé la fonction On avec le bouton AN tourner le bouton AI pour visualiser les sigles Slo Temps de raccord entre le courant de soudure et le courant de remplissage cratèr...

Page 15: ...e fil sort pour 50 cm sans passage de courant La sortie du fil de la torche peut être réglée de 5 à 50 centimètre avec le bouton AN La fonction étant rappelée pourra être activée On ou désactivée Off 14 Fac usine Le but est de rétablir les valeurs usine du poste à souder définies par le fabricant lors de la première fourniture La fonction étant sélectionnée le display AM visualise noP commande le ...

Page 16: ...ventionnel VOYANT AR allumé Choisir le numéro PRG d après le diamètre du fil à utiliser le type et la qualité du matériel et type de gaz en suivant l instruction située à l intérieur de la pièce latérale mobile Régler les fonctions présentes dans le sous menu d après les indications du paragraphe Fonctions de service Régler la vitesse du fil et la tension de soudure avec respectivement avec le bou...

Page 17: ...n presencia de polvo gas o vapores ex plosivos Manejar con cuidado las bombonas y los reguladores de presión utilizados en las operaciones de soldadura COMPATIBILIDAD ELECTROMAGNÉTICA Este aparato se ha construido de conformidad a las indi caciones contenidas en la norma armonizada IEC 60974 10 Cl A y se deberá usar solo de forma profesional en un ambiente industrial En efecto podrían presentarse ...

Page 18: ... sin recalentarse I2 Corriente de soldadura U2 Tensión secundaria con corriente I2 U1 Tensión nominal de alimentación 1 50 60Hz Alimentación monofásica 50 o 60 Hz I1 Max Corriente max absorbida a la correspon diente corriente I2 y tensión U2 I1 ef Es el máximo valor de la corriente efectiva absorbida considerando el factor de servicio Normalmente este valor corresponde al cali bre del fusible de t...

Page 19: ...el par de valores elegidos para la soldadura podrían generar arcos inestables y con salpicaduras LED AG Hold No es seleccionable Señala que los tamaños visualizados por los displays AL y AM normalmente Amperios y Voltios son los utilizados en la última soldadura realizada Se activa al final de cada soldadura LED AH Tensión En todos los procesos de soldadura indica que el display AM visualiza la te...

Page 20: ... es el valor aconsejado Para los parámetros colocados en el interior de la función de servicio MIG que vienen visualizados por el display AM ver el párrafo funciones de servicio Cuandolamáquinaestáenerror visualizaelcorrespondiente código de error comprendido entre 1 y 99 Tecla de selección AO A cada presión selecciona el tipo de proceso elegido la selección es visualizada por los LEDs AP AQ AR LE...

Page 21: ...ante más de 30 segundos la bomba se desactiva y la máquina se pone en error ERR 75 2 TRG Selección entre 2 tiempos 4 tiempos 3 niveles la selección 2t y 4t se puede hacer por medio de la tecla de selección AU sin entrar en las funciones de servicio 2t la máquina inicia a soldar cuando se pulsa el pulsador y se interrumpe cuando se suelta 4t para iniciar la soldadura pulsar y soltar el pulsador ant...

Page 22: ...ana a la soldadura que se deba realizar Se determina así la velocidad de referencia Para activar la función actuar como sigue A Activar la función girando la manecilla AN hasta que aparezca la palabra On en el display AM B Girar la manecilla AI hasta que aparezca la sigla FdP frecuencia doble pulsación en el display AL El display AM visualiza la sigla OFF apagado Girar la manecilla AN para selecci...

Page 23: ...resión Montar la antorcha Para averiguar que la ranura de los rodillos corresponda al diámetro del hilo utilizado abrir el lateral móvil quitar la cubierta CA desbloquear los rodillos sujeta hilo mediante la manecilla de regulación de la presión BN sustituir los rodillos y volver a montar la cubierta CA Ver fig 5 Fig 5 BN BN CA Montar la bobina del hilo e introducir el hilo en el arrastre y en la ...

Page 24: ...e de forma que exista un aislamiento seguro entre el lado primario y el lado secundario de la máquina Evitar que los hilos puedan entrar en contacto con partes en movimiento o WIRING DIAGRAM COLOUR CODE A BLACK B RED C GREY D WHITE E GREEN F PURPLE G YELLOW H BLUE K BROWN J ORANGE I PINK WIRING DIAGRAM COLOUR CODE L PINK BLACK M GREY PURPLE N WHITE PURPLE O WHITE BLACK P GREY BLUE Q WHITE RED R GR...

Page 25: ...25 ...

Page 26: ...26 ...

Page 27: ...ER CORD 25 STRAIN RELIEF 26 MOTOR WITH FAN KIT 27 FAN SUPPORT 28 FIXED SIDE PANEL 29 TORCH SUPPORT 39 SWITCH 40 SOCKET 41 FRONT PANEL 42 ADAPTOR BODY POS DESCRIPTION 45 PROTECTION 46 RING NUT 47 PROTECTION 30 PRIMARY IMPEDANCE 31 BOTTOM 32 REST 33 COOLING TUNNEL BODY 34 PROTECTION CASE 35 PROTECTION CASE 36 EARTH CABLE 37 FRONT PANEL 38 SOCKET 39 ADAPTOR PROTECTION 40 ADAPTOR BODY 41 HANDLE SUPPOR...

Page 28: ...LE SUPPORT 105 AXLE 106 FIXED WHEEL When ordering spare parts please always state the ma chine item and serial number and its purchase data the spare part position and the quantity POS DESCRIPTION 107 CAP 108 WHEELS BRACKET 109 SWIVELING WHEEL 110 PILLAR BRACKET 111 POWER SOURCE SUPPORT 113 LID 114 REST ...

Reviews: