background image

Installation Instructions

CMS491P2 / CMS492P2 / CMS491CP2 / CMS492CP2

5

LEGEND

TOOLS REQUIRED FOR INSTALLATION

PARTS

Tighten Fastener

Apretar elemento de fijación

Befestigungsteil festziehen

Apertar fixador

Serrare il fissaggio

Bevestiging vastdraaien

Serrez les fixations

Loosen Fastener

Aflojar elemento de fijación

Befestigungsteil lösen

Desapertar fixador

Allentare il fissaggio

Bevestiging losdraaien

Desserrez les fixations

Phillips Screwdriver

Destornillador Phillips

Kreuzschlitzschraubendreher

Chave de fendas Phillips

Cacciavite a stella

Kruiskopschroevendraaier

Tournevis à pointe cruciforme

Adjust

Ajustar

Einstellen

Ajustar

Regolare

Afstellen

Ajuster

            A (1)
 [EGX-SF2 Power
 Conditioner Outlet]

       B (1)
[Outlet cover]

Grounding screw installed at factory. (See Figure 4)

         10-32
grounding screw

Earthing symbol IEC 60418 No. 5019
affixed adjacent to grounding terminal

C (2)

[Clip - not used]

Summary of Contents for CMS491CP2

Page 1: ...491P2 CMS491CP2 CMS492P2 CMS492CP2 Powered Ceiling Storage Boxes Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description CMS491P2 CMS492P2 CMS491CP2 CMS492CP2 ...

Page 2: ... WARRANTY It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT DANGER TO REDUCE THE RISK OF ELECTRIC SHOCK 1 Always turn off power at source before installing the outlet WARNING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Always turn off power at...

Page 3: ...Installation Instructions CMS491P2 CMS492P2 CMS491CP2 CMS492CP2 3 DIMENSIONS CMS491P2 DIMENSIONS INCHES MILLIMETERS CMS491CP2 ...

Page 4: ...CMS491P2 CMS492P2 CMS491CP2 CMS492CP2 Installation Instructions 4 DIMENSIONS continued DIMENSIONS INCHES MILLIMETERS CMS492P2 CMS492CP2 ...

Page 5: ...esapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster A 1 EGX SF2 Power Conditioner Outlet B 1 Outlet cover Grounding screw installe...

Page 6: ...r structure directly at an equipment grounding conductor terminal of the applicable derived system or service Where installed in accordance with the provisions of this section this equipment grounding conductor shall also be permitted to pass through boxes wire ways or other enclosures without being connected to such enclosures Informational Note Use of an isolated equipment grounding conductor do...

Page 7: ...entical in size and insulation material and thickness to the grounded and ungrounded circuit supply conductors except that it is green with or without one or more yellow stripes is to be installed as part of the circuit that supplies the outlet Refer to Table 250 122 of the National Electrical Code regarding the appropriate size of the grounding conductor NOTE Pressure terminal or pressure splicin...

Page 8: ...ee Figure 3 OR See Figure 4 8 Tighten two Phillips screws to secure outlet box to EGX SF2 housing See Figure 3 OR See Figure 4 Figure 3 Figure 4 9 Make sure grounding screw is properly installed See Figure 5 WARNING ELECTRICAL SHOCK HAZARD Turn off power to device before performing service or connecting to outlet Figure 5 10 Remove 6 32 x 1 2 Phillips flat head screw and lock washer from front of ...

Page 9: ...from front of box See Figure 5 or See Figure 7 NOTE Make sure LED light on outlet box lines up with hole location on faceplate B See Figure 7 Figure 7 Outlet Box Use NOTE The PROTECTED light indicates that the surge protection circuitry is active and operational Figure 8 11 CMS491CP2 shown as example B housing box not shown for clarity lock washer LED light PROTECTED indicator light ...

Page 10: ...CMS491P2 CMS492P2 CMS491CP2 CMS492CP2 Installation Instructions 10 ...

Page 11: ...Installation Instructions CMS491P2 CMS492P2 CMS491CP2 CMS492CP2 11 ...

Page 12: ...4 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief a products division of Milestone AV Technologies 8800 002794 Rev00 2016 Milestone AV Technologies www chiefmfg com 03 16 ...

Reviews: