background image

Installation Instructions

CMA101

5

INSTALLATION

WARNING:

Do NOT attach to vertical mounting surfaces

such as walls or angled ceilings!

WARNING:

IMPROPER INSTALLATION CAN LEAD TO

MOUNT FALLING CAUSING SEVERE PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! It is the installer’s
responsibility to make certain the structure to which the
mount is being attached is capable of supporting five times
the weight of the CMA mount and all attached equipment.
Reinforce the structure as required before installing the
mount.

NOTE:

The following instructions assume a suitable mounting
structure and surface exists prior to installation.

NOTE:

Proceed to

Wood Stud Installation

 section,

Solid

Concrete Installation

section, or

Threaded Rod

Installation

section.

Wood Stud Installation

1.

Carefully determine required mounting location.

IMPORTANT ! :

This will require knowing the lens to

screen distance. See projector specifications for details
on determining this distance.

WARNING:

IMPROPER INSTALLATION CAN RESULT IN

SERIOUS PERSONAL INJURY OR DAMAGE TO
EQUIPMENT! Structural members

MUST

 be capable of

supporting five times the combined weight of all equipment
being mounted.

IMPORTANT ! :

The CMA101 is designed to be mounted to

double 2" x 4" wood stud cross bracing (4" on center) between
two ceiling joists with a maximum drywall covering of 5/8".

2.

Using the CMA101 as a guide, mark four mounting hole
locations. Hole locations must be centered on 2" x 4" cross
braces. (See Figure 1)

3.

Drill four 7/32" diameter x 2-1/2" long pilot holes. (See
Figure 1)

Figure 1

4.

Align four mounting holes in CMA101 with four pilot holes.
(See Figure 2)

5.

Secure CMA101 to structure using four 5/16" x 3-1/2" Grade
2 lag bolts (not included). (See Figure 2)

Figure 2

2

3

x 4

x 4

5

Summary of Contents for CMA101

Page 1: ...I O N I N S T R U C T I O N S Ceiling Plate Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product D...

Page 2: ...rious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equip...

Page 3: ...concrete 5 16 x 3 1 2 minimum length Grade 2 lag bolts Qty 4 Fischer UX10 concrete anchors OR Toggler AF8 concrete anchors Qty 4 3 Install to Unistrut 5 16 18 threaded rod Qty 4 5 16 Grade 2 nuts Qty...

Page 4: ...l Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche By Hand A mano Von Hand Com a m o A mano Met de hand la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabe a...

Page 5: ...ion 1 Carefully determine required mounting location IMPORTANT This will require knowing the lens to screen distance See projector specifications for details on determining this distance WARNING IMPRO...

Page 6: ...de mark four mounting hole locations on ceiling See Figure 3 3 Drill four 3 1 4 deep pilot holes See Figure 3 For Fischer UX10 anchors use a 3 8 drill bit For Toggler AF8 anchors use a 5 16 drill bit...

Page 7: ...uded onto each threaded rod 3 Install CMA101 onto threaded rods inserting the rods into the four holes on top of the CMA101 4 Secure the threaded rods to the CMA101 with one 5 16 nut not included and...

Page 8: ...918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 214...

Reviews: