20.0 STARTING UP
COMPRESSOR WITH AUTOMATIC START
BEFORE CARRYING OUT ANY OPERATION ON THE COMPRESSOR, ENSURE THAT THE ELECTRIC POWER
SUPPLY HAS BEEN DISCONNECTED.
20.1 PREPARING FOR SETTING UP
After checking everything as indicated in Section. 12, follow the instructions in Fig. 17.
- Fit the sound-deadening panels Ref. 1 Fig 17.
These parts are packed inside the bodywork.
20.2 PRELIMINARY CHECKS
- Check the oil level Ref. 1 Fig. 17 when supplied the compressor is filled with oil;if the oil is not at the correct level, top
off with the same oil as the original type.
If more than 3 months have passed between the inspection in the factory and the date of installation, lubricate the screw
before starting up, following the procedure described below:
- Remove the side maintenance panel using the supplied key.
- Remove the cover Ref. 3 Fig. 17
- Remove the air filter Ref. 4 Fig. 17
- Pour a little oil into the suction unit.
- Reassemble the air filter Ref. 4 Fig. 17
- Reassemble the cover Ref. 3 Fig. 17
If more than 6 months have passed between the inspection in the factory and the date of installation, consult
the manufacturer.
FIG. 17
1
1
1
2
3
4
Oil