11/2008
Chicago Pneumatic Compressors
Page 20
62 305 549 65
15.0 ROUTINE MAINTENANCE
BEFORE CARRYING OUT ANY MAINTENANCE IT IS MANDATORY TO STOP THE COMPRESSOR AND
DISCONNECT IT FROM THE MAIN POWER.
The maintenance jobs described in this Section may be carried out by the user.
The more complex maintenance jobs which require professionally skilled personnel are listed in the Section on
GENERAL MAINTENANCE FOR TRAINED PERSONNEL (See Section. 21.0)
15.1 GENERAL INFORMATION
Routine maintenance must be carried out according to the maintenance schedule affixed to the compressor.
15.2 MAINTENANCE SCHEDULE
OPERATIONS THAT MAY BE CARRIED OUT BY THE USER
OPERATIONS THAT REQUIRE SKILLED PERSONNEL; THESE OPERATIONS ARE ILLUSTRATED IN PART
“B” OF THIS MANUAL.
These maintenance intervals are recommended for work environments that are not dusty and are will ventilated.
For particularly dusty environments, double the frequency of maintenance.
Every 50 working hours
Drain condensate from the SUMP TANK
Check the oil level
Clean the filtering panel
Every 500 hours
Clean the air suction filter
(see control board LED)
Check belt tension
Every 2000 hours
Change the oil filter
(see control board LED)
Change the suction filter
(see control board LED)
Every 4000 hours
Clean the finned surface of the air-oil cooler
Change the oil separating filter
(see control board LED)
Every 8000 hours
Change the oil
(see control board LED)
BEFORE CARRYING OUT ANY MAINTENANCE IT IS MANDATORY TO STOP THE COMPRESSOR AND
DISCONNECT IT FROM THE MAIN POWER.
MAINTENANCE ON THE ELECTRICAL COMPONENTS CAN ONLY BE PERFORMED BY QUALIFIED
TECHNICIANS OR AUTHORIZED FACTORY PERSONNEL.
CAUTION
When the compressed air cools, part of the moisture sucked in by the compressor condenses. In order to protect the
dryer against the risk of an ice plug forming, it is essential to check regularly that the condensate drains are operating
properly :
On the compressed air storage reservoir and on the filters :
• With a manual drain, drain regularly according to the moisture content of the ambient air.
• With an automatic drain, set the draining cycle accordingly and check that the drain is in good working condition.
This recommendation is also fundamental in a circuit comprising an absorption dryer (risk of saturation of the
alumina).