11/2008
Chicago Pneumatic Compressors
Page 22
62 305 549 65
15.4
CHECK OIL LEVEL AND TOP OFF
- Switch off the compressor using the button Ref. 1 Fig. 14: the compressor will stop after running unloaded for a few
seconds.
- Turn off main power and lockout disconnect Ref. 3 Fig. 14
-
Remove the side maintenance panel using the supplied key.
-
Wait a few minutes for the foam in the sump tank to abate.
-
Check the oil level on the indicator Ref. 4 Fig. 14
-
If the oil level is under the minimum, top off.
USE OIL OF THE SAME TYPE AS THAT ALREADY IN THE COMPRESSOR; DO NOT MIX DIFFERENT TYPES OF
OIL.
BEFORE CARRYING OUT ANY OPERATION ON THE COMPRESSOR, ENSURE THAT THE ELECTRIC POWER
SUPPLY HAS BEEN DISCONNECTED.
- Slowly open the fill port Ref. 6 Fig. 14
- Top off to maximum level Ref. 4 Fig. 14, with oil of the same type in the compressor.
- Replace the cap on the fill ports Ref. 6 Fig. 14.
- Close the side maintenance panel using the supplied key
15.5 CLEANING THE FILTRATION PANEL
- Press the “STOP” button Ref. 1 Fig. 15
- Switch off the compressor
- Turn off main power and lockout disconnect Ref. 3 Fig. 15.
- Remove the filter panel Ref. 4 Fig. 15.
- Clean the filter panel with water,
do not use solvents.
- Once the operation has been completed, reassemble the filter panel.
FIG. 15
3
4
4
1
2
HP 40-50
4
HP 60