TECHNICAL DATA
Model
Voltage
Amp. Max
Starting
Current
Capacitor life
Full Charging Time
Weight
CP90250
12 V
8 000 A peak
1 300 A
1 000 000 cycles
30 sec. By running engine
6-7 Hours by AC adaptor
8.5 kg
CP90500
12 V
9 000 A peak
1 800 A
1 000 000 cycles
30 sec. By running engine
6-7 Hours by AC adaptor
9.5 kg
MACHINE TYPE(S)
• This product is designed to help to start vehicle engine in case of emergency. No other use permitted. For professional use only.
• Please read the instructions carefully before starting the machine.
OPERATION
The Batteryless Jump Starter relies on the instant recharging of supercapacitors rather than stored electric energy like batteries. There-
fore, it can be stored for years without regular recharges. It’s totally maintenance free!
CAUTION: Before first use make sure to charge the Batteryless Jump Starter with the supplied automatic
charger adaptor for at least 8 hours.
Checking the power level of the Batteryless Jump Starter
• Press the yellow test button for 2-5 seconds. The power level will be displayed with LEDs lights.
• Make sure the unit is fully charged before using it (the 5 LEDs lights must be on).
• If the power level lit until the yellow LEDs light, the device should be recharged before use.
Charging the Batteryless Jump Starter with the automatic charger adaptor
• Make sure the clamps are secure in their respective designated holders before charging.
• Make sure the charger adaptor and Batteryless Jump Starter are placed in a well-ventilated, dry, non-flammable area during charge.
• Simply plug the charger adaptor into the AC power outlet and then into the socket on the Batteryless Jump Starter .
• Turn the main switch to the “ON” position.
• The charger included with your device is fully automatic and may be left on and connected when the Batteryless Jump Starter is fully
charged.
To keep the Batteryless Jump Starter ready to use, recharge it at least every 90 days with the supplied automatic charger adaptor. However,
when not in use it is strongly recommended to always keep it connected to the supplied automatic charger adaptor to be used anytime.
Charging the Batteryless Jump Starter through the clamps with a running vehicle
Note: Charging with a running vehicle requires much shorter time than charging with the automatic charger adaptor.
Caution: Charging with a running vehicle is not automatic and requires the operator to manually observe the
charging of the Batteryless Jump Starter and the power level status. Always make sure the vehicle is run
-
ning and never leave the Batteryless Jump Starter connected for long time and charging unattended.
Caution : Make sure to use this 12V Batteryless Jump Starter with a 12V battery or vehicle.
1. Make sure the vehicle ignition is in the “OFF” position.
2. Make sure the main switch of the Batteryless Jump Starter is on the “OFF” position
3. Connect first the positive (red) clamp to the positive terminal of the battery
4. Then connect the negative (black) clamp to the negative terminal of the battery, or to the block of the engine or to the frame of the
vehicle (ground)
5. Make sure the device is stable and the cables are not in the path of moving belts, fans, etc…
6. Make sure the reverse polarity alarm is not making a loud noise and blinking.
7. Once the clamps are positioned correctly, start the vehicle
8. Turn the main switch to the “ON” position
The Batteryless Jump Starter will charge automatically within a few seconds.
Caution : DO NOT leave it connected for more than 2 minutes.
To check the power level status, press the yellow test button for 2-5 seconds.
9. When the Batteryless Jump Starter is charged, turn the main switch to “OFF” position.
10. Always disconnect the clamps one at a time starting with the negative (black) and then the positive (red).
11. Store both clamps in their respective designated holders.
EN
English
(English)
CP90250 & CP90500
Batteryless Jump Starter
Ultra Capacitor