CP86150/CP86200/CP86300/CP86500
Hydraulic press
5. Maintenance instruction
Caution
Do not use damaged/deformed product. If abnormal noise or vibration occurs, stop use immediately, then inspect and ask
manufacturer for help.It is recommended that this inspection be made by a manufacturer’s or supplier’s authorized repair facility.
Caution
The greatest single cause of failure in hydraulic units is dirt.
•
Keep the service jack clean and well lubricated to prevent foreign matter from entering the system. If the jack has been exposed to rain,
snow, sand, or grit, it must be cleaned before it is used.
•
Store the jack, with pistons completely retracted, in a well-protected area where it will not be exposed to corrosive vapors, abrasive dust, or
any other harmful elements.
•
Periodically check the condition of the product.
•
Store the product in dry and non-corrosion environment.
•
Owners and/or operators should be aware that repair of this equipment may require specialized knowledge and facilities. It is recommended
that an annual inspection of the product be made by a manufacturer’s or supplier’s authorized repair facility and that any defective parts,
decals, or safety labels or signs be replaced with manufacturer’s or supplier’s specified parts. A list of authorized repair facilities is available
from the manufacturer or supplier, please call them for help.
•
Any product that appears to be damaged in any way, is found to be worn, or operates abnormally SHALL BE REMOVED FROM SERVICE
UNTIL REPAIRED. It is recommended that necessary repairs be made by a manufacturer’s or supplier’s authorized repair facility if repairs are
permitted by the manufacturer or supplier.
•
Only attachments and/or adapters supplied by the manufacturer shall be used.
6. Trouble Shooting
No.
Fault
Cause
Remedy
1
The pump is working, while the ram
can't work
1.The oil pipe loosed the ram is leaking
1.Checking the connecting situation of oil
pipes, replace the oil seals
2
When open release vavle, the ram
can’t reset
1.The oil pipe loosed
2.No enough space un pump
3.The ram become invalid
1.Checking the connecting situation of oil pipes
2.Open exhaust valve
3.Replace the ram
3
Manual normal, while ram can’t
work
1.Release valve not complete closed
2.air in system
1.check the release valve
2.Purge away the air according manual
4
The ram can't fully work
1.The oil is not enough
1.Add oil
5
Oil leaking
1.Seal kits broken
2.Screw parts loosed
1.Replace the seal kits
2.Tighten the screw parts
7. Declaration of conformity
We : CHICAGO PNEUMATIC Tool Co. LLC 1800 Overview Drive Rock Hill, SC 29730 - USA
Declare that the product(s): CP86150/CP86200/CP86300/CP86500
Serial Number: From 00001 to 99999
Machine type(s): Hydraulic press Origin of the product: China
is in conformity with the requirements of the council Directives on the approximation of the laws of the Member States relating : to
“Machinery“ 2006/42/EC (17/05/2006)
applicable harmonised standard(s) : EN 1494:2000 + A1:2008
Name and position of issuer: Nicolas Lebreton ( R&D Manager)
Place & Date: Saint-Herblain, 11/12/2014
Technical file available from EU headquarter. Nicolas Lebreton R&D manager LLC CP Technocenter 38, rue Bobby Sands - BP10273 44800
Saint Herblain - France
Original Instructions are in English. Other languages are a translation of the original instructions.
Copyright 2014, Chicago Pneumatic Tool Co. LLC
All rights reserved. Any unauthorized use or copying of the contents or part thereof is prohibited. This applies in particular to trademarks, model
denominations, part numbers and drawings. Use only authorized parts. Any damage or malfunction caused by the use of unauthorized parts is
not covered by Warranty or Product Liability..
The design has been validated according to: ASME ASP-2010