Technical Data
Technical data
Air flow at max. output (l/s)
8.1
Air flow at max. output (cfm)
17.1
Free speed (rpm)
70
Max output Power (kW)
0.37
Max output Power (hp)
0.5
Min starting torque (Nm)
200
Min starting torque (ft.lb)
148
Output Spindle (mm)
12.7
Output Spindle (in.)
Stall torque (Nm)
220
Stall torque (ft.lb)
162
Torque at max. output (Nm)
110
Torque at max. output (ft.lb)
81
Weight ( kg)
2.6
Weight (lb)
5.8
Declarations
EU DECLARATION OF INCORPORATION
We
CHICAGO PNEUMATIC Tool Co. LLC
, 1815 Club-
house Road, Rock Hill, SC 29730 - USA, declare under our
sole responsibility that this product (with name, type and se-
rial number, see front page) fulfils the following essential re-
quirements of Machinery Directive 2006/42/EC, and must
not be put into service until the final machinery, into which it
is to be incorporated, has been declared in conformity with
that Directive. It is in conformity with the following Direc-
tive(s):
2006/42/EC (Annex I, clauses 1.1, 1.2 (excluding 1.2.4.3),
1.3, 1.4, 1.5, 1.6, 1.7)
Harmonized standards applied:
DIN EN 4414:2010, DIN EN 1127-1:2011, DIN EN
80079-36:2016, DIN EN 80079-37:2016, DIN EN ISO
12100:2010
The relevant technical documentation was compiled and was
communicated in accordance with Machinery Directive
2006/42/EC part B of Annex VII. Authorities can request the
technical file in electronic form from:
Pascal Roussy, R&D Manager, Ets Georges Renault, 38 rue
Bobby Sands, BP10273 44818 Saint Herblain, France
Saint-Herblain, 09/12/2019
Pascal ROUSSY
Signature of issuer
Regional Requirements
WARNING
This product can expose you to chemicals including
lead, which is known to the State of California to cause
cancer and birth defects or other reproductive harm. For
more information go to
Safety
DO NOT DISCARD - GIVE TO USER
WARNING Read all safety warnings, instructions, il-
lustrations and specifications provided with this
product.
Failure to follow all instructions listed below may result
in electric shock, fire, property damage and/or serious
injury.
Save all warnings and instructions for future refer-
ence.
WARNING All locally legislated safety rules regard-
ing installation, operation and maintenance shall be
respected at all times.
Statement of Use
• For professional use only.
• This product and its accessories must not be modified in
any way.
• Do not use this product if it has been damaged.
• If the product data or hazard warning signs on the prod-
uct cease to be legible or become detached, replace with-
out delay.
• The product must only be installed, operated and ser-
viced by qualified personnel in an industrial environ-
ment.
Intended Use
This motor is designed to be incorporated into a fixed or
moving machine. It is either for right hand rotation only, left
hand rotation only, or reversible rotation and should be
mounted by the flange or threaded nose only, as appropriate.
No other use permitted.
The risk of motors being the source of ignition of a poten-
tially explosive atmosphere is extremely small. The user is
responsible for assessing the risks associated with the whole
machine into which the motor is to be incorporated.
Product Specific Instructions
Connecting the air supply
When the compressed air supply is connected to the inlet, the
direction of rotation will be as shown in the figure below. If
the exhaust air is to be piped away, a hose should be con-
nected to the exhaust outlet.