Page 8
SKU 97047
For technical questions, please call 1-800-444-3353.
SpeCiFiCAtionS
Continuous Power
1,000 Watts
Peak Power
2,000 Watts
Input Voltage
12 Volts Nominal DC (11-1 Volts possible)
Outlet Voltage
11 VAC at 0 Hz
AC Receptacles
Three 3-Prong, Grounded, Polarized Outlets
Fuse
40 Amps, 4 Qty
(internal, for replacement by a qualified technician only)
Thermal Overload
1° F (8° C)
Low Voltage Alarm
10.V
Automatic Shut Down
10V
Recommended Input Cord
Battery Cables (not included)
#2 AWG or larger cables recommended
unpACKing
When unpacking, check to make sure that the item is intact and undamaged. If
any parts are missing or broken, please call Harbor Freight Tools at the number shown
on the cover of this manual as soon as possible.
Set up inStruCtionS
read the entire iMportAnt SAFetY inForMAtion section at the
beginning of this manual including all text under subheadings therein
before set up or use of this product.
risk of Fire. the positive battery terminal connection must
be the lASt connection made and must be done with the
inverter’s power switch off.
this inverter must only be connected to batteries with
a nominal output voltage of 12 volts. lower voltage will
not operate the inverter properly, and more voltage could
damage the inverter or the device being powered. if more
than one 12 volt battery is to be used, the batteries must
be connected in a parallel circuit; batteries connected in a
series circuit will produce too much voltage.
For the power inverter to work properly, your power source must provide 12 volts
DC, and the power source must provide enough current (i.e., 4 amps to oper-
ate the load of 0 Watts or under).
wArning
wArning
CAution
CAution