Generator
- Power: 10,000 watts (rated), 11,000 (peak) at 240 vaC;
5000 watts (5500 peak) at 125 vaC.
- alternator: single phase, 9.6 kva. voltage: 125 / 240 vaC, 60Hz.
- nominal current: 80 amps at 125 vaC, 40 amps at 240 vaC.
- outlets: 120 vaC standard; 120 vaC twist-lock 3-prong
(nEMa# l5-30), 120/240 vaC 4-prong twist-lock (nEMa# l14-30).
- Four circuit breaker system, resettable.
Engine
- 18 HP robin subaru®: EH63 with heavy cast aluminum sleeve.
- 3600 rPM
- EPa and Carb. approved; Four cycle engine, 653-cc displacement.
- Gas tank: twin 7.0 gallon (total); Fuel: unleaded gasoline.
- automatic “low oil” shut off.
- oil capacity and type: 52.48 Fl. oz.; at 32~86°F: F-saE 30;
Below 32° F: F-saE 5W-30.
- starter: 12 volt electric starter.
Frame
dual isolator mounts with full roll cage
Estimated run Time 11 hours with full tank under ½ load
Weight
308 lbs.
IMPORTANT PRECAUTIONS BEfORE STARTING ENGINE
ADD OIL. This generator requires oil and fuel to be added before starting. Attempting
to start the engine without oil will ruin the engine and void the warranty.
This generator is not intended to power sensitive electronic equipment without the
addition of an appropriate line conditioner (sold separately).
Before using the generator, read and understand the Robin Subaru
®
Engine Opera-
tion, Maintenance, and Parts Manual. Also read the safety precautions in this manual
which should always be followed to reduce the risk of personal injury and damage to
equipment.
SAVE THIS MANUAL
You will need the manual for the safety warnings and precautions, assembly instructions,
operating and maintenance procedures, parts list and diagram. keep your invoice with this
manual. Write the invoice number on the inside of the front cover. keep the manual and
invoice in a safe and dry place for future reference.
WARNING!
READ AND UNDERSTAND ALL INSTRUCTIONS. Failure to follow all instruc-
tions listed below may result in electric shock, fire, and/or serious injury.
SAVE THESE INSTRUCTIONS
GENERAL SAfETY RULES
Read all instructions before installing or using this generator!
1. Ensure installation meets all applicable safety, and local and national electrical codes.
Have installation performed by a qualified, licensed electrician and building contractor.