Item 68849 

        

concrete floor) at least 1 foot away from all flammable 

objects, such as drapes or walls.  Keep a fire 

extinguisher and a smoke detector in the area.  

Frequently monitor the charger and battery 

while charging.

27. This product is not a toy.  

Keep it out of reach of children.

28. Verify that there are no utility lines or 

hardware in or near the workpiece.  

This is especially critical for plunge cuts.

29. Do not depress the spindle lock when 

starting or during operation.

30. People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields in 

close proximity to heart pacemaker could cause 

pacemaker interference or pacemaker failure.  In 

addition, people with pacemakers should: 

• Avoid operating alone. 

• Do not use with power switch locked on. 

• Properly maintain and inspect to avoid 

electrical shock. 

• Properly ground power cord.  Ground Fault Circuit 

Interrupter (GFCI) should also be implemented 

– it prevents sustained electrical shock.

31. WARNING: Some dust created by power sanding, 

sawing, grinding, drilling, and other construction 

activities, contains chemicals known [to the State 

of California] to cause cancer, birth defects or 

other reproductive harm.  Some examples of these 

chemicals are: 

• Lead from lead-based paints 

• Crystalline silica from bricks and cement or other 

masonry products 

• Arsenic and chromium from 

chemically treated lumber 

Your risk from these exposures varies, depending 

on how often you do this type of work.  To reduce 

your exposure to these chemicals: work in a well 

ventilated area, and work with approved safety 

equipment, such as those dust masks that are 

specially designed to filter out microscopic particles.  

(California Health & Safety Code § 25249.5, 

et seq.

)

32. WARNING: Handling the cord on this product will 

expose you to lead, a chemical known to the State 

of California to cause cancer, and birth defects or 

other reproductive harm. Wash hands after handling.  

(California Health & Safety Code § 25249.5, 

et seq.

)

33. The warnings, precautions, and instructions 

discussed in this instruction manual cannot 

cover all possible conditions and situations 

that may occur.  It must be understood by the 

operator that common sense and caution are 

factors which cannot be built into this product, 

but must be supplied by the operator.

Vibration Safety

This tool vibrates during use.  Repeated or long-term 

exposure to vibration may cause temporary or permanent 

physical injury, particularly to the hands, arms and 

shoulders.  To reduce the risk of vibration-related injury:

1.  Anyone using vibrating tools regularly or for an 

extended period should first be examined by a 

doctor and then have regular medical check-ups 

to ensure medical problems are not being caused 

or worsened from use.  Pregnant women or 

people who have impaired blood circulation to 

the hand, past hand injuries, nervous system 

disorders, diabetes, or Raynaud’s Disease should 

not use this tool.  If you feel any medical or 

physical symptoms related to vibration (such as 

tingling, numbness, and white or blue fingers), 

seek medical advice as soon as possible.

2.  Do not smoke during use.  Nicotine reduces 

the blood supply to the hands and fingers, 

increasing the risk of vibration-related injury.

3.  Use tools with the lowest vibration 

when there is a choice.

4.  Include vibration-free periods each day of work.

5.  Grip tool as lightly as possible (while still keeping 

safe control of it).  Let the tool do the work.

6.  To reduce vibration, maintain the tool as 

explained in this manual.  If any abnormal 

vibration occurs, stop use immediately.

 SAVE THESE INSTRUCTIONS.

Circular Saw Safety Warnings (cont.)

SAFETY

OPERA

TION

MAINTENANCE

SETUP

Summary of Contents for 68849

Page 1: ...not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included When unpacki...

Page 2: ...nal injury IMPORTANT SAFETY INFORMATION General Power Tool Safety Warnings Read all safety warnings and instructions Failure to follow the warnings and instructions may result in electric shock fire a...

Page 3: ...by an appropriate standards agency Unapproved safety equipment may not provide adequate protection Eye protection must be ANSI approved and breathing protection must be NIOSH approved for the specific...

Page 4: ...wn cord Contact with a live wire will also make exposed metal parts of the power tool live and shock the operator 6 When ripping always use a rip fence or straight edge guide This improves the accurac...

Page 5: ...is released 14 DO NOT USE THIS SAW WITH THE SAW HELD UPSIDE DOWN IN A VISE The saw is not designed for such use and cannot be used safely in that position 15 Do not use to cut logs tree limbs or unev...

Page 6: ...afety Code 25249 5 et seq 32 WARNING Handling the cord on this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm...

Page 7: ...ndard Association and the National Electrical Code 2 Double insulated tools may be used in either of the 120 volt outlets shown in the preceding illustration See Outlets for 2 Prong Plug Extension Cor...

Page 8: ...g Setup Before Use Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product TO PREVENT SER...

Page 9: ...Handle Trigger 36 Battery Pack not included Battery Button Bevel Adjusting Knob 42 Plate 50 Saw Blade 6 Fence Adjusting Knob 45 Depth Adjusting Knob 53 Laser Switch 38 Laser Guide 14 Trigger Lock But...

Page 10: ...lange 2 3 Use the lever on the Lower Guard 10 to raise the Guard and remove the Blade 6 Leave the inner flange in place 4 Install the new blade with the directional arrow on the blade pointing the sam...

Page 11: ...g the first few charging cycles A fully discharged Battery Pack will take about 1 hour to fully charge Recharging the Battery Pack for more than 1 hour can damage the battery cells 7 While charging th...

Page 12: ...8 After completing the cut release the trigger Make sure that the Movable Guard closes immediately 9 To prevent accidents turn off the tool and disconnect the Battery Pack after use 10 Clean then sto...

Page 13: ...e are no obstructions reinsert the Battery Pack according to its shape it should only fit one way and press firmly until the Battery Pack locks in place 2 Make sure Charger is connected and operating...

Page 14: ...S TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List Part Description Qty 1 Blade Bolt 1 2 Outer Flange 1 3 Screw M4...

Page 15: ...800 444 3353 Item 68849 Assembly Diagram 1 2 3 5 4 6 7 10 9 8 8 13 12 11 8 4 14 12 15 25 26 27 28 30 29 24 19 18 23 22 21 20 37 38 39 40 41 52 53 42 44 45 47 48 46 34 33 32 31 36 35 41 17 16 16 16 51...

Page 16: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLI...

Reviews: