background image

Page 7

For technical questions, please call 1-800-444-3353.

Item 65570 

        

extension Cords

1. 

Grounded

 tools require a three wire extension cord.  

Double Insulated

 tools can use either 

a two or three wire extension cord.

2.  As the distance from the supply outlet increases, 

you must use a heavier gauge extension cord.  

Using extension cords with inadequately sized wire 

causes a serious drop in voltage, resulting in loss of 

power and possible tool damage.  

(See table a.)

3.  The smaller the gauge number of the wire, the 

greater the capacity of the cord.  For example, 

a 14 gauge cord can carry a higher current 

than a 16 gauge cord.  

(See table a.)

4.  When using more than one extension cord to make 

up the total length, make sure each cord contains at 

least the minimum wire size required.  

(See table a.)

5.  If you are using one extension cord for more 

than one tool, add the nameplate

 

amperes 

and use the sum to determine the required 

minimum cord size.  

(See table a.)

6.  If you are using an extension cord outdoors, make 

sure it is marked with the suffix “W-A” (“W” in 

Canada) to indicate it is acceptable for outdoor use.

7.  Make sure the extension cord is properly wired 

and in good electrical condition.  Always replace 

a damaged extension cord or have it repaired 

by a qualified electrician before using it.

8.  Protect the extension cords from sharp objects, 

excessive heat, and damp or wet areas.

taBle a:  ReCOmmenDeD minimum WiRe 

GauGe FOR eXtenSiOn CORDS* (120/240 vOlt)

nameplate

ampeReS

(at full load)

eXtenSiOn CORD 

lenGth

25´ 50´ 75´ 100´ 150´

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

* Based on limiting the line voltage drop to five volts at 

150% of the rated amperes.

Symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

v~

Volts Alternating Current

a

Amperes

n0 xxxx/min.

No Load Revolutions per Minute (RPM)

WARNING marking concerning Risk 

of Eye Injury.  Wear ANSI-approved 

safety goggles with side shields.

Read the manual before 

set-up and/or use.

WARNING marking concerning 

Risk of Hearing Loss.  

Wear hearing protection.
WARNING marking 

concerning Risk of Fire.  

Do not cover ventilation ducts.

Keep flammable objects away.

WARNING marking concerning 

Risk of Electric Shock.  

Properly connect power cord 

to appropriate outlet.

Sa

Fet

Y

Ope

R

ati

O

n

m

aintenan

C

e

Setup

Summary of Contents for 65570

Page 1: ...uded When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 800 444 3353 as soon as possible Save This Manual Keep this manual for the safet...

Page 2: ...lt in minor or moderate injury Addresses practices not related to personal injury Important Safety Information General Power Tool Safety Warnings Read all safety warnings and instructions Failure to f...

Page 3: ...hile you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury 2 Use personal protective equipment A...

Page 4: ...contact hidden wiring or its own cord Contact with a live wire will make exposed metal parts of the tool live and shock the operator 2 Use clamps or another practical way to secure and support the wor...

Page 5: ...arms and shoulders To reduce the risk of vibration related injury 1 Anyone using vibrating tools regularly or for an extended period should first be examined by a doctor and then have regular medical...

Page 6: ...user reducing the risk of electric shock See 3 Prong Plug and Outlet 2 The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool The green...

Page 7: ...tdoor use 7 Make sure the extension cord is properly wired and in good electrical condition Always replace a damaged extension cord or have it repaired by a qualified electrician before using it 8 Pro...

Page 8: ...erein before set up or use of this product TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Squeeze and release the Trigger and unplug the tool from its electrical outlet before performing any proc...

Page 9: ...2 Release the Chuck to close it 3 To install the new Saw Blade rotate and hold the Chuck counterclockwise while inserting the Saw Blade and pushing it in to its deepest position 4 Release the Chuck to...

Page 10: ...Trigger to ensure that the Trigger Lock is off 3 Holding the Saw with the Trigger released plug the Power Cord into a 120V electrical outlet 4 To begin sawing gripping the saw firmly with both hands r...

Page 11: ...reach full speed then slowly rotate the tool on the Pivot Shoe as the Blade contacts the work piece Hold the tool firmly 5 Continue to slowly rotate the tool until the Blade has penetrated through th...

Page 12: ...EACH USE inspect the general condition of the tool Check for loose hardware misalignment or binding of moving parts cracked or broken parts damaged electrical wiring and any other condition that may...

Page 13: ...ding section on page 6 Performance decreases over time 1 Accessory dull or damaged 2 Carbon brushes worn or damaged 1 Keep cutting accessories sharp Replace as needed 2 Have qualified technician repla...

Page 14: ...ead Tapping Screw 4 60 Power Cord 1 61 Cable Sleeve 1 62 Right Handle 1 63 Pan Head Tapping Screw 6 64 Locking Spring 1 65 Rotation Switch 1 66 Brand Label 1 67 Pan Head Screw 2 68 Pan Head Screw 2 Pa...

Page 15: ...Page 15 For technical questions please call 1 800 444 3353 Item 65570 Assembly Diagram Safety Operation Maintenance Setup...

Page 16: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you This warranty is expressly in lieu of all other warranties express or impli...