Edge MAXX
Troubleshooting
6-29
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
POSSIBLE CAUSE
SOLUTION
Compressed Air Supply Sys-
tem Error
1. Electrical problem within
compressed air system
circuitry.
Test the system using the CHI panel.
Refer to the
CHI PANEL OPERATION
bulletin,
Testing
section.
Look at the Wago I/O control modules
for each air valve. An LED lights for
each valve. Refer to the
SCHEMAT-
ICS
. When the LED does not come on
when the valve is supposed to open,
the I/O module is defective and must
be replaced.
There is an open circuit between the
control circuit board MPC1 and the
actuator.
Actuator on the valve is defective and
must be replaced.
•
-
-
-
2. A supply hose is obstruct-
ed or detached.
Check the hose to the valve in ques-
tion. Reattach, clear the obstruction or
replace.
•
3. Air filter/regulator with
auto drain is dirty.
Clean the air filter/regulator with auto
drain. Refer to the
PREVENTIVE
MAINTENANCE
chapter,
Semi-Annu-
al PM
section,
Clean Air Filter/Regu-
lator/Auto Drain
procedure.
•
TOC
INDEX
Summary of Contents for Edge MAXX
Page 1: ...EDGE MAXX Dual Input Large Piece Spreader Feeder INSTRUCTION MANUAL...
Page 12: ......
Page 102: ......
Page 132: ......
Page 196: ......
Page 228: ...3038 010k Edge Maxx PL 14 This page intentionally left blank TOC INDEX PL TOC...
Page 232: ...3038 010k Edge Maxx PL 18 This page intentionally left blank TOC INDEX PL TOC...
Page 250: ......
Page 252: ...SC 2 460V Motor Circuit TOC INDEX SC TOC...
Page 255: ...Edge Maxx 3210 393d SC 5 This page intentionally left blank TOC INDEX SC TOC...
Page 259: ...Edge Maxx 3210 393d SC 9 This page purposely left blank TOC INDEX SC TOC...
Page 273: ......
Page 274: ......
Page 275: ......
Page 276: ......
Page 278: ......
Page 280: ......