The Alarm jumper block (J1) is used to configure the output drive for alarms. Normal
operation (3 & 2) is active high drive of Pizo buzzer or LED. If it is desired to drive a relay
or high current lamp, configure jumper for 1 & 2 for active low alarm drive of 100 mA.
J1 ALARM
ID
Pin
Function
STATE
J1-1
1
Relay Drive
1&2
Active Low Alarm
J1-2
2
Alarm Out
-
-
J1-3
3
LED Drive
3&2
Active High Alarm
Voltage Drive mode. 0V when alarm off, 3.3
volts when alarm on
–
Drive small Pizo
buzzer or reed relay. Source 50 mA
Open Collector Ground drive. Open circuit
when alarm off, sink to ground when alarm
on. Used to ground relay to drive higher
current device. Sinks up to 100 mA