Default SeaGauge configuration is to drive external analog sensors directly with no other
devices connected to any sensor
–
Direct Mode.
Do not apply any voltage to sensors configured for Direct Mode. SeaGauge provides
a 2.5V reference voltage output to each sensor in Direct Mode which may damage
other devices.
Sensor Plug C (green) Direct Mode
Pin Channel Function
Pull-
Up Ω
Pull-
Down Ω
Series Ω
P1
A8
Volt 1
-
10K-
100K
P12
A11
Volt 2
-
10K
100K
P2
A9
Fluid 1
300/50*
10K/None*
50K
P11
A10
Fluid 2
300/50*
10K/None*
50K
P3
A0
Temperature 1
300*/50
10K/None*
50K
P10
A2
Temperature 1
300*/50
10K/None*
50K
P4
A1
Pressure 1
300/50*
10K/None*
50K
P9
A3
Pressure 2
300/50*
10K/None*
50K
P5
A4
Pressure 3
300/50*
10K/None*
50K
P8
A7
Pressure 4
300/50*
10K/None*
50K
P6
A5
Temperature 3
300
-
50K
P7
A6
Temperature 4
300
-
50K
* Default Value
NOTE
–
PULL UP RESISTANCE IS CONFIGURED BY ON-BOARD DIP
SWITCHES
NOTE
–
PULL DOWN RESISTANCE IS CONFIGURED BY ON-BOARD DIP
SWITCHES
NOTE
–
WHEN USING UNGROUNDED EGT PROBES, BE SURE TO STRAP
EGT+ TO GROUND. EGT SUPPORT IS AN OPTION ON SEAGAUGE UNITS