10
4.2
-
Electrical hookup
The machine has a power cable (3x1.5 mm² x 2.5 m) and a 16A Shuko plug. Connect
the 230 V 50 Hz machine by installing a 10A
Δ
I = 0.03A residual-current device on the
line. Also check that the information on the machine's nameplate match the
specifications given in the delivery and shipping documents, and that both the master
switch and cable are easily accessible while the machine is in use.
PART 4 - INSTALLATION
4.1
-
Positioning
The Softcooker has been designed to be used with normal cooking tanks (1/1 or 2/1
H. 200,
as shown fig. 5
), and in general with tanks of capacity up to 43 litres and a
maximum depth of 200 mm.
The Softcooker must be supported by a special profile member (
ref. 1 fig. 5
) on the
edge of the tank, and secured with the knob (
ref. 2 fig. 5
).
Fill the tank with water, taking care to observe the maximum and minimum level
markings. If the tank is filled to below its minimum level, the Softcooker's level sensor
will prevent it from starting, the machine will emit beeps and an error message (H2o
Low) will appear on the display.
CAUTION:
Follow the instructions to the letter and do
not exceed the
maximum level
marked on the side of the machine
(
fig 5
); avoid
splashing when filling the tank or loading it with the bags.
Fig. n°5
1
2
7
LEGEND
1
Handle
8 Heating element
2
Master power switch ON-OFF
9 Impeller
3
Fuses
10 Power cable
4
Touch screen display with controls
11 Machine locking knob
5
Heating element guard
12
NTC2
safety sensor
6
Level sensor
13 NFC reader (only for NFC version)
7
NTC1
temperature sensor
14 Wireless core probe (optional)
1.7
-
Protective and safety equipment
Before using the machine, make sure it and its safety equipment are properly
positioned and in good working order.
Check that everything is present and correct at the start of each shift.
If anything is lacking, report it to the maintenance supervisor.
-
Heating element guard (ref. 5 fig. 2)
: prevents contact with the heating element
and with the impeller, which can seriously injure the user.
-
Automatic run dry protection (ref. 6 fig. 2)
: if the level of water falls below the
permitted minimum (
fig. 5
) the machine stops operating and an error message
displays (
H2O Low
).
-
Shut down device (ref. 7 and 12 fig. 2)
: should the temperature sensors reading
not agree, due to a fault in either of them, the machine is shut down and error
message displays (
PROB
).
1.8 - Structure of the machine
8
7
6
10
9
11
12
Fig. n°2
4
1
2
3
5
13