13
Cleaning & Maintenance
•
Before cleaning, disconnect the Microwave from the electricity supply.
•
Once the unit has cooled completely, wipe with a damp & soapy cloth.
•
DO NOT submerge the Microwave in water or use water sprays to clean
it
•
Always clean your Chefmaster Microwave daily
•
Use a vacuum cleaner to clean the air intake & exhaust vents
Troubleshooting
Fault
Possible Cause
Solution
No power
Socket problem / Unit is
not plugged / Blown fuse
Check the socket / Plug the
unit / Change the fuse
The power is on but the
unit does not carry out the
instruction correctly
Door is not closed /
Touch pad is locked /
Touch pad failure
Close the door / Unlock the
touch pad / Contact with
your Chefmaster distributor
Transportation and Storage
Please handle your Microwave with care to prevent any damage to the unit
and internal parts. The Microwave should be stored somewhere which is
ventilation and non-corrosive gas.
Do not store any flammable objects near the equipment.
Technical Information
HEB082 – Microwave oven
Voltage: 230v~50Hz
Power: 1000watt
Weight : 14.7 Kgs
Dimensions : 511x432x311mm
•
Chefmaster Microwave are supplied with a 3 pin plug and lead with a 13
amp fuse
•
Appliance must be earthed
•
If in doubt contact a qualified electrician or your Chefmaster distributor