the DC Power input (i.e. do not connect 2 power supplies directly to 1 reader). J6 and J14
are wired in parallel, allowing the installer to daisy chain a second RF Only system; use
only the approved power supply for your region; in FCC use 10043582. The third bottom
row connector port (J3) is for future expansion.
The DC power wire must be 3 conductor (2C w/ drain wire), 18 AWG or greater,
maximum 10m [32.8ft]. The PSU drain wire is grounded to chassis GND with crimp
terminal. A small bracket with ground lugs will be described in the installation manual.
The connector pinout for DC power INPUT connector is below:
Table 2: Power Connector Pin Assignments
PIN # ON TR4300 (J6/J14)
COLOR
SIGNAL
EXAMPLE
1
Bare wire (shield/
drain wire)
Chassis Ground
(GND)
2
Red
+24V
3
Black
GND
Note: Other internal factory wiring will be detailed in reference sections in the Field Service manual.
6.0
DEVICE LABELING
Each NEO will have a label, found in the base region, which indicates this specific unit’s
Model Name, part number, revision and the serial number of the unit manufactured, as
well as regulatory information. For example:
FCC ID: DO4NEO
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesirable operation.