background image

Dear Users 

Thank you for using digital adjustable spanner. This 
manual will help you to use the many features of your 
new digital adjustable spanner.

 Before operating the 

adjustable spanner, please read this manual 
completely

, and keep it nearby for future reference. 

MAIN FEATURES 

Digital torque value readout

+/- 3% accuracy (20%~100% of F.S.)

CW operation

Peak Hold and Track Mode Selectable

Buzzer and LED indicator for the 9 pre-settable
target torques

Four Units Selectable(N-m, ft-lb, in-lb, kg-cm)

50 or 250  data memory for recall and joint
torque auditing

Communication functions

Auto Sleep after about 5 minutes idle

Both AA and rechargeable batteries are compatible

The “Moving Jaw” has a special design with the
positioning portion for keeping the same constant
distance with different size of bolts.(This patent has
been approved by several countries)

NAMES AND FUNCTIONS OF PARTS 

1. Jaw
2. Positioning Portion
3. Knurl
4. Communication Port
5. LCD Display
6. Buttons
7. Buzzer
8. Battery Compartment
9. Battery Cap
10. Anti-slip Handle
11. Torque Value

12. Units Selection
13. Pre-setting No.
14. P(Peak Hold)/T(Track)

Mode

15. LED Indicator
16. Unit Selection/Setting

Button

17. Power On/Clear Button
18. Pre-setting No. Selection

Button

19. Up Button
20. Down Button

Summary of Contents for DAW-060N

Page 1: ...OWNER S MANUAL Digital Adjustable Spanner DWA Series ...

Page 2: ...all and joint torque auditing Communication functions Auto Sleep after about 5 minutes idle Both AA and rechargeable batteries are compatible The Moving Jaw has a special design with the positioning portion for keeping the same constant distance with different size of bolts This patent has been approved by several countries NAMES AND FUNCTIONS OF PARTS 1 Jaw 2 Positioning Portion 3 Knurl 4 Communi...

Page 3: ... lb 867 kg cm DAW 135N 5 26 135N m 99 5 ft lb 1195in lb 1378 kg cm DAW 135N 5 30 135N m 99 5 ft lb 1195in lb 1378 kg cm DAW 200N 5 30 200N m 147 5ft lb 1770in lb 2041 kg cm DAW 200N 10 41 200N m 147 5ft lb 1770in lb 2041 kg cm DAW 340N 10 41 340N m 250 7ft lb 3009in lb 3469 kg cm 2 3 Accuracy C 3 CW Communication N No R Yes C N R DAW 060N DAW 135N DAW 340N ...

Page 4: ...LEDs 2 Red 10 Green Pre setting No 9 sets Operation Mode Peak hold Track Unit Selection N m in lb ft lb kg cm Head Type Spanner Open End Size mm 3 5 27 Button 5 Battery 4 AA X 2 Operating Temperature 10 60 Storage Temperature 20 70 Humidity Up to 90 non condensing Drop Test 1 m Vibration Test 5 10G Environmental test 6 Pass Electromagnetic compatibility test 7 Pass NOTE Accuracy is guaranteed from...

Page 5: ...n Pre setting No 9 sets Operation Mode Peak hold Track Unit Selection N m in lb ft lb kg cm Head Type Spanner Open End Size mm 3 5 30 Button 5 Battery 4 AA X 2 Operating Temperature 10 60 Storage Temperature 20 70 Humidity Up to 90 non condensing Drop Test 1 m Vibration Test 5 10G Environmental test 6 Pass Electromagnetic compatibility test 7 Pass NOTE Accuracy is guaranteed from 20 to 100 full sc...

Page 6: ... Pre setting No 9 sets Operation Mode Peak hold Track Unit Selection N m in lb ft lb kg cm Head Type Spanner Open End Size mm 3 10 41 Button 5 Battery 4 AA X 2 Operating Temperature 10 60 Storage Temperature 20 70 Humidity Up to 90 non condensing Drop Test 1 m Vibration Test 5 10G Environmental test 6 Pass Electromagnetic compatibility test 7 Pass NOTE Accuracy is guaranteed from 20 to 100 full sc...

Page 7: ...Jaw has a special design concept with Positioning Portion which keeps constance distance from the center of the bolts to the center of the handle when the bolt head is fixed to Positioning Portion And this will keep the same accuracy with different sizes and spec of bolts 4 Two AA batteries Toshiba carbon zinc battery 5 Horizontal and vertical test 6 Environmental test a Dry heat b Cold c Damp hea...

Page 8: ...otate it tightly according to the following figures POWER ON AND RESETTING THE SPANNER Press to power on the digital adjustable spanner Usually press to reset the digital adjustable spanner before using it ATTENTION If an external force is applied to the spanner during power on reset or wake up period an initial torque offset will exist in the memory Direction of Battery and Cap Installation ...

Page 9: ...ring communication period send appears the sleep function is disabled RESETTING THE SPANNER Press together will reset the spanner If the spanner does not function normally Press together to reset the spanner LOW BATTERY VOLTAGE PROTECTION If the battery serial voltage is in low voltage status the wrench will display a battery symbol and then turn off after a while ...

Page 10: ...pplied more than 110 of torque of the spec 2 The maximum capacity for Pre setting No is 9 sets 3 The Pre setting No is cyclic Note1 2 3 Pre setting M9 Pre setting M1 Press Press Pre setting M3 Pre setting M2 4 2 1 3 Up Down Button 3 Unit Selection Setting 2 1 Pre setting No 4 Power On Clear 2 ...

Page 11: ...ORQUE VALUE Note 1 The Unit Selection is cyclic Pre setting Torque Value Decrease Max Torque Value Press Press Increase Max Torque Value Pre setting Unit N m Press Unit Selection kg cm Press Press Unit Selection ft lb Unit Selection in lb ...

Page 12: ...ODE SELECTION Note 1 Please skip this procedure and continue to the next step Set Peak Track mode Press Set Peak Track mode Record No Note 1 Track Mode Long Press Peak Hold Mode Clear Record Press Note 1 Press for Selection Press ...

Page 13: ...r 80 85 90 95 and 97 5 of target torque 3 When reaching the target torque the green and red LED will be on at the same time Apply Torque Current Torque Value Current Torque Value Note 1 START System initial Buzzer Red LED Approached Target Torque Setting Target Torque Green LED Reach 80 of Target Torque Reach Target Torque Reach 80 of Target Torque Note 2 Note 3 ...

Page 14: ...ans the wrench s memory is full and the next value record can not be written in Please refer the Peak Hold Mode Recorded Value Review section to clear the momory records 3 The green LED will be on for 80 85 90 95 and 97 5 of target torque 4 When reaching the target torque the green and red LED will be on at the same time Note 1 Buzzer Green LED Reach 80 of Target Torque Flashing Apply Torque Relea...

Page 15: ... This function is not supported on all type of models 5 Communication mode is for uploading record data to PC 6 Communication mode is also for calibration of torque spanner Please contact your local dealer for more information Press Peak Hold Track Mode Set Peak Track Mode Auto Change Record No Note 2 Record Value Long Press Press Note 3 Note 1 Communication Clear Record Press Peak Hold Track Mode...

Page 16: ...rogram first select the correct COM port No Next select the file path to save the uploaded data Finally press upload button to transmit the torque records to PC The uploaded data is then shown on the column and saved in the csv file Use Microsoft Excel to view csv file Precaution 1 Communication function is only supported on some models Check the model no and its specification before using communi...

Page 17: ... dust or sand as this could cause serious damage 10 Do not apply excessive force to the LCD panel 11 Apply torque slowly and graspe the center of the handle Do not apply load to the end of handle BATTERY MAINTENANCE 1 When the spanner is not used for an extended period of time remove the battery 2 Keep a spare battery on hand when going on a long trip or to cold areas 3 Do not mix battery types or...