Procedure for Smart-1 6000-L/6000-XL Appliances
Quantum Smart-1 600-M/6000-L/6000-XL Appliances Replacing Line Cards | 15
Disconnect the DC power connectors from the DC PSUs.
6.
Remove the hook-and-loop straps that hold and secure the system cables, if they interfere with the
PSU removal.
7.
Remove any other attached cables, if necessary.
8.
Remove the appliance from the rack.
See the booklet for illustrated installation procedures.
9.
Put the Electrostatic Discharge (ESD) grounding strap on your wrist and attach the other end to a
grounding point.
10.
Remove the appliance cover:
a.
Use a flat or a Phillips head screwdriver to rotate the latch release lock counter-clockwise to
the unlocked position.
b.
Lift the latch.
c.
Slide the cover back.
The tabs on the cover should disengage from the guide slots on the appliance.
d.
Hold the cover on both sides and lift the cover away from the appliance.
Item
Description
1
Latch release lock
2
Latch
3