43
FOXDRIVE-R14
FOXDRIVE-R14 DT
english
18.0 - GRIPPER CLOSING
Closing of the grippers can be advanced or delayed by adjusting the guides which
cause it to close (fig. 10.C):
-move up to advance
-move down to delay
19.0 - TRANSPLANT UNIT IN WORK PHASE
19.1 - Use the drive wheel adjustment device (fig. 11) to set the transplant units to
a horizontal position in relation to the ground (fig. 11.A).
19.2 - Check that an oscillation space of approximately 2 cm remains between
the beam stop and the linkage (fig. 12).
This is essential to allow the transplant unit to adapt itself to any unevenness in the
ground.
20.0 - TRANSPLANT DISTANCE
INTER-ROW SPACING: minimum 50 cm for single frame version (fig. 13)
minimum 25 cm for double frame version (DT) (fig. 14)
Inter-row spacing must be adjusted with the machine coupled to the tractor and with
the lift unit lowered.
Clean the hexagonal axis and the frame of any soil or other dirt, slacken the screws
(fig. 15.A), position the unit at the desired distance, sliding it along the frame. Do not
carry out these operations by hammering with metal objects as this could cause
serious damage to the components.
cm 2
A
A
A
A
FOXDRIVE-R14
min. 50
min. 25
FOXDRIVE-R14 DT
FIG. 11
FIG. 12
FIG. 14
FIG. 15
FIG. 13
Summary of Contents for FOXDRIVE-R14 DT
Page 17: ...16 FOXDRIVE R14 FOXDRIVE R14 DT italiano A B C F D A FIG 25 FIG 26...
Page 33: ...32 FOXDRIVE R14 FOXDRIVE R14 DT fran ais A B C F D A FIG 25 FIG 26...
Page 49: ...48 FOXDRIVE R14 FOXDRIVE R14 DT english A B C F D A FIG 25 FIG 26...
Page 65: ...64 FOXDRIVE R14 FOXDRIVE R14 DT deutsch A B C F D A Abb 25 Abb 26...
Page 81: ...80 FOXDRIVE R14 FOXDRIVE R14 DT espa ol A B C F D A FIG 25 FIG 26...
Page 85: ...84...