20
■
Analogue reading: to get the resistance in
Ω
, multiply the reading
on the 50 scale by the reading coefficient shown in the table.
7 - RESISTANCES
Never test a resistance on a live circuit.
If the “Voltest” light comes on, presence of a voltage U > 10 V
AC/DC. Unplug the leads immediately and cut off the voltage
before making the resistance measurement.
■
Connect to the terminals of the circuit or the component to test.
Do not use the A AC input on unprotected current
transformers
From 7 A to 10 A, limited to 10 minutes on, 5 minutes off up
to 40°C maximum
(1) At the terminals (2) As % of the reading (rdg) from 5 to 100% of the range
(3) As % of end of scale
A DC
400
µµµµµ
A
4 mA
40 mA
400 mA
1 A 10 A
Voltage drop
(1)
400 mV
450 mV 650 mV
1 V
Digital
Max reading
399.9
µ
A 3.999 mA 39.99 mA 399.9 mA
1.000 A
10.00 A
Accuracy
(2)
1.5% rdg ± 2 counts
Max reading
500
µ
A
5 mA
50 mA
500 mA
1 A
10 A
Scale
50
10
Analogue
Reading
coefficient
x 10
x 0.1
x 1
x 10
x 0.1
x 1
Accuracy
(3)
2.5%
Protection
Fuse 1 A HPC
Fuse 10 A
HBC
NB: Accuracies given in the frequency reference range 35 to 500 Hz.
(1) and (2) Additional error of 1% for a crest factor FC
≤
3 (3) At the terminals
(4) As % of the reading (rdg) from 5 to 100% of the range (5) As % of end of scale
V AC
and
V AC/DC
400
µµµµµ
A
4 mA
40 mA
400 mA
1 A 10 A
Voltage drop
(3)
400 mV
450 mV 650 mV
1 V
Max reading
399.9
µ
A 3.999 mA 39.99 mA 399.9 mA
1.000 A
10.00 A
Accuracy
2% rdg ± 5 counts
Digital
on AC
(4)
Accuracy
4.5% rdg ± 5 counts
on AC/DC
(4)
Max reading
500
µ
A
5 mA
50 mA
500 mA
1 A
10 A
Scale
50
10
Analogue
Reading
coefficient
x 10
x 0.1
x 1
x 10
x 0.1
x 1
Accuracy
(5)
2.5%
Protection
Fuse 1 A HPC
Fuse 10 A
HBC
(1) (2)
■
Digital reading: if necessary, press the following keys,
HOLD to hold in memory and for display backlighting
From 7 A to 10 A, limited to 10 minutes on, 5 minutes off up to 40°C
maximum
906129433-GB-Ed.4-NF CA 5011.p65
05/03/02, 16:12
20