Chauvet TFX-DC4 User Manual Download Page 3

 

TFX-DC4 User Manual  

2006-01-27 5:37:23 PM

 

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

 

TFX-DC4 Stage 4 Controller 

 

Power cord 

 

Manual with warranty card 

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of 

the fixture or refer to the fixture

s specifications ch

art. A fixture

s listed current rating is its average 

current draw under normal conditions. All fixtures must be powered directly off a switched circuit and 

cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the 

rheostat or dimmer channel is used solely for a 0% to 100% switch. Before 

applying power to a fixture, check that the source voltage matches the 

fixture

s requirement. Check the fixture or device carefully to make sure that 

if a voltage selection switch exists that it is set to the correct line voltage you 

will use. 

Warning! 

Verify that the power select switch on your unit matches the line voltage applied. All 
fixtures must be connected to circuits with a suitable Earth Ground.  

Safety Instructions 

 

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that 
they also receive this instruction booklet. 

 

Always make sure that you are connecting to the proper voltage and that the line voltage you are 
connecting to is not higher than that stated on decal or rear panel of the fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no 
flammable materials close to the unit while operating. 

 

In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit 
by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please 
contact the nearest authorized technical assistance center. Always use the same type spare parts. 

 

Don

t connect the device to a dimmer pack.

 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on the cord. 

 

Do not operate this device under 113

°

 F ambient temperature conditions. 

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or attempt 
any repairs yourself. In the unlikely event your unit may require service, please contact 
CHAUVET. 

 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance?  

AC Voltage Switch 

 

Summary of Contents for TFX-DC4

Page 1: ...929 5560 www chauvetlighting com TFX DC4 Stage 4 Controller USER MANUAL ON OFF SOUND SENSITIVITY SOUND SENSITIVITY SPEED FULL ON BLACK OUT STA GE 4 CH 1 CH 2 CH 3 CH 4 MIC FUSE 5A FUSE 5A FUSE 5A FUSE 5A POWER MIN MAX MIN MAX CHASE CHASE SOUND 16 PATTERNS AUTO FLASH 16 PATTERNS SOUND ...

Page 2: ...3 WHAT IS INCLUDED 3 UNPACKING INSTRUCTIONS 3 AC POWER 3 SAFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 GENERAL OVERVIEW 4 PRODUCT OVERVIEW 5 OPERATING INSTRUCTIONS 6 SETUP 6 OPERATION 6 APPENDIX 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 7 TECHNICAL SPECIFICATIONS 8 ...

Page 3: ...voltage you will use Warning Verify that the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground Safety Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the prop...

Page 4: ... outlets on board General Overview The TFX DC4 is a very easy to use 4 channel chaser switch pack that also doubles as a 4 channel dimmer Five preset programs can be selected instantly from an on board rotary switch The programs consist of a chase sound chase two programs with 16 patterns each that can be executed in both auto and sound modes and a flash program The Stage 4 can be set to either Fu...

Page 5: ...anently to fader control or all on 6 Blackout button Temporarily shuts off all output from the pack 7 Mic Internal microphone used during sound chase mode 8 Sound sensitivity knob Adjust the microphones sensitivity for optimum performance 9 Speed knob Adjust chase speed when not set to a sound mode 10 Chase select knob Select any one of the five built in chase programs 1 2 3 4 5 6 7 8 9 10 230V 11...

Page 6: ...res without internal motors Operation 1 The Stage 4 is a plug and play controller pack Simply connect your lighting fixtures to the outlets in the rear and turn the power switch on 2 Choose a chase program by turning the 5 position rotary knob 3 Adjust the Sound Sensitivity knob to enhance the playback of the chase while in a sound activated chase program Likewise adjust the Speed knob while in an...

Page 7: ...eported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim for items such as missing component part damage not related to shipping and concealed damage must be made within seven 7 days of receiving merchandise General Troubleshooting Applies to Symptom Sol...

Page 8: ... in Width 130 mm 5 13 in Height 70 mm 2 75 in Weight 1 7 Kg 3 76 lbs POWER Switch selectable power setting 110V 60Hz or 230V 50Hz THERMAL Maximum ambient temperature 45 C 113 F FUSE Output 4 20mm Glass 5A Fast Blow Main 15A Resettable circuit breaker ORDERING INFORMATION Stage 4 TFX DC4 Fuse 5A P170FUSE005 ...