background image

  

Operating 

Instructions 

TFX-D12 User Manual 

9  

2004-11-11/11:32 

Dmx fail 

Dmx fail 

Prog08 

Hold –

 The dimmer 

will hold the last dmx 
signal received.  
 

Analog – 

The 

dimmer will revert to 
the Analog input 
signal.  
 

ProgXX - 

 Will start 

internal programs 1-
12. 

Setup Menu 

Action 

™

 

1) Press 

the 

MENU

 button to enter the setup 

menu. 

2) 

There are 6 menu items to choose from; 
Dmx fail, Phase Correction, Dmx addr, 
Preheat, Curve and Preset.  

3) Press 

the 

UP

 and 

DOWN

 buttons to scroll 

menu items.  

4) Press 

ESC

 to exit the setup menu. 

 

DMX Fail [Dmx fail] 

The DMX Fail feature allows the user to select how the dimmer will behave if you were to loose the 

DMX controller’s signal to the dimmer.  

Action 

™

 

1) Press 

the 

MENU

 button to enter the setup 

menu. 

2) Press 

the 

UP

 and 

DOWN

 buttons to scroll 

menu items until you reach 

[Dmx fail]

3) Press 

MENU 

to enter the sub-menu. 

4) 

If it were running the built-in scene 08 it 
would display as per the illustration on the 
right.  

5) Press 

the 

UP/DOWN

 buttons to select one 

of the following; 

[Hold]

[Analog]

[Prog.01-12]

 

H O L D ,   A N A L O G  

1) Whether 

you 

choose 

Hold 

or 

Analog

 press 

the 

ESC 

button to confirm and exit. 

 

P R O G . 0 1 - 1 2  

1) Press 

the 

ESC

 button to confirm. 

2) 

Select a chasing speed from 0.1 to 20 
seconds using the 

UP/DOWN

 button. 

(Hold the UP/DOWN buttons for two seconds to change 
speed quickly.)

 

3) Press 

the 

ESC 

button to confirm setting. 

 

Dmx fail 

(Hold) or (Analog) 

Speed 

00.3s 

Summary of Contents for Stage Dimmer 12

Page 1: ...h Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2004 11 11 11 32 TFX D12 Stage Dimmer 12 USER MANUAL UP MENU DOWN ESC DMX 1 2 CH DIGIT ALMODULE DIMMER...

Page 2: ...Control Wiring 7 DMX512 7 Analog 0 10VDC 7 OPERATING INSTRUCTIONS 8 START MENU 8 MENU NAVIGATION 8 Setup Menu 9 DMX Fail Dmx fail 9 Hold Analog 9 Prog 01 12 9 Phase Correction Pha corr 10 DMX Address...

Page 3: ...risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate vent...

Page 4: ...dles Forced air cooling DMX Signal Indicator 10A Circuit breaker Module air intake I O Panel Knockout rear cover panel BUTTON FUNCTION MENU Access the set up and menu functions UP Scroll menu function...

Page 5: ...orced air cooling and the following guidelines should be applied during installation 1 The rack enclosure must maintain a 4 inch minimum clearance on the entire left side of the dimmer rack The rack e...

Page 6: ...codes to determine the proper wire type and wiring methods for your regional installation Input Power SINGLE PHASE THREE PHASE L L1 L2 L3 N N N N E E E 1 phase 3 wire 120 240 VAC 120 Amps 50 60Hz POW...

Page 7: ...1 DGND 2 DATA 3 DATA ANALOG 0 10VDC Input 15 pin M D Sub Pin Signal 1 Channel 1 2 Channel 2 3 Channel 3 4 Channel 4 5 Channel 5 6 Channel 6 7 Channel 7 8 Channel 8 9 Channel 9 10 Channel 10 11 Channel...

Page 8: ...led and shortly after will enter standby mode Menu Navigation First line displays dimming levels of each channel Second line displays the channel A C 10 12 1 2 3 4 5 6 7 8 9 A B C 1 2 3 4 5 6 7 8 9 A...

Page 9: ...will behave if you were to loose the DMX controller s signal to the dimmer Action 1 Press the MENU button to enter the setup menu 2 Press the UP and DOWN buttons to scroll menu items until you reach...

Page 10: ...button to enter the sub menu BLOCK 1 Press the ESC button to confirm 2 Press UP DOWN buttons to select the start address between 001 and 512 SINGLE 1 In Chan 1 Single Channel mode press MENU to change...

Page 11: ...Chan 1 1 In Chan 1 Single Channel mode press MENU to change between the channel and its start address as noted by the cursor 2 In Chan press UP DOWN buttons to select channels 1 12 In 001 press UP DO...

Page 12: ...buttons to select between All Single Channel mode ALL All 1 Press UP DOWN to select the master dimmer level value between 000 100 for all channels SINGLE CHANNEL Chan 1 1 In Chan 1 Single Channel mod...

Page 13: ...one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order...

Page 14: ...without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sur...

Page 15: ...ut 4 wire GD 120 230 VAC 120 Amps 50 60Hz OUTPUT CAPACITY 120VAC 12 channels 1200 Watts per channel 120VAC 230VAC 12 channels 2300 Watts per channel 230VAC OUTPUT PANEL Hard wired terminal blocks OVER...

Reviews: