PPENDIX

 

DMX Primer 

There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A 

fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user 

must assign a starting address on the fixture that indicates the first channel reserved in the controller. 

There are many different types of DMX controllable fixtures and they all may vary in the total number 

of channels required. Choosing a start address should be planned in advance. Channels should 

never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is 

set incorrectly. You can however, control multiple fixtures of the same type using the same starting 

address as long as the intended result is that of unison movement or operation. In other words, the 

fixtures will be slaved together and all respond exactly the same.  

DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is 

where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which 

the fixtures are connected is not important and has no effect on how a controller communicates to 

each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures 

using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The 

shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET 

carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’) 

F I X T U R E   L I N K I N G  

 

 

 

 

 

Note! 

If you use a controller with a 5 pin DMX output connector, you will need to use a 5 
pin to 3 pin adapter. CHAUVET Model No: DMX5M. 
The chart below details a proper cable conversion: 
 

3

 

P

IN TO 

5

 

P

IN 

C

ONVERSION 

C

HART

 

C

ONDUCTOR

 

3 Pin Female (output) 

5 Pin Male (Input) 

G

ROUND

/S

HIELD

 

Pin 1 

Pin 1 

D

ATA 

(

 

-

 

)

SIGNAL

 

Pin 2 

Pin 2 

D

ATA 

(

 

+

 

)

 SIGNAL

 

Pin 3 

Pin 3 

D

O NOT USE

 

 

Do not use 

D

O NOT USE

 

 

Do not use 

 

COMMON

DMX +

DMX -

INPUT

OUTPUT

3

1

3

2

1

3

2

Resistance 120 
ohm 1/4w between 
pin 2 (DMX -) and 
pin 3 (DMX +) of 
the last fixture.

Termination reduces signal errors and to 
avoid signal transmission problems and 
interference, it is always advisable to connect 
a DMX signal terminator. 

DMX connector configuration 

Summary of Contents for Stage Dimmer 12

Page 1: ...h Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2004 11 11 11 32 TFX D12 Stage Dimmer 12 USER MANUAL UP MENU DOWN ESC DMX 1 2 CH DIGIT ALMODULE DIMMER...

Page 2: ...Control Wiring 7 DMX512 7 Analog 0 10VDC 7 OPERATING INSTRUCTIONS 8 START MENU 8 MENU NAVIGATION 8 Setup Menu 9 DMX Fail Dmx fail 9 Hold Analog 9 Prog 01 12 9 Phase Correction Pha corr 10 DMX Address...

Page 3: ...risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating The unit must be installed in a location with adequate vent...

Page 4: ...dles Forced air cooling DMX Signal Indicator 10A Circuit breaker Module air intake I O Panel Knockout rear cover panel BUTTON FUNCTION MENU Access the set up and menu functions UP Scroll menu function...

Page 5: ...orced air cooling and the following guidelines should be applied during installation 1 The rack enclosure must maintain a 4 inch minimum clearance on the entire left side of the dimmer rack The rack e...

Page 6: ...codes to determine the proper wire type and wiring methods for your regional installation Input Power SINGLE PHASE THREE PHASE L L1 L2 L3 N N N N E E E 1 phase 3 wire 120 240 VAC 120 Amps 50 60Hz POW...

Page 7: ...1 DGND 2 DATA 3 DATA ANALOG 0 10VDC Input 15 pin M D Sub Pin Signal 1 Channel 1 2 Channel 2 3 Channel 3 4 Channel 4 5 Channel 5 6 Channel 6 7 Channel 7 8 Channel 8 9 Channel 9 10 Channel 10 11 Channel...

Page 8: ...led and shortly after will enter standby mode Menu Navigation First line displays dimming levels of each channel Second line displays the channel A C 10 12 1 2 3 4 5 6 7 8 9 A B C 1 2 3 4 5 6 7 8 9 A...

Page 9: ...will behave if you were to loose the DMX controller s signal to the dimmer Action 1 Press the MENU button to enter the setup menu 2 Press the UP and DOWN buttons to scroll menu items until you reach...

Page 10: ...button to enter the sub menu BLOCK 1 Press the ESC button to confirm 2 Press UP DOWN buttons to select the start address between 001 and 512 SINGLE 1 In Chan 1 Single Channel mode press MENU to change...

Page 11: ...Chan 1 1 In Chan 1 Single Channel mode press MENU to change between the channel and its start address as noted by the cursor 2 In Chan press UP DOWN buttons to select channels 1 12 In 001 press UP DO...

Page 12: ...buttons to select between All Single Channel mode ALL All 1 Press UP DOWN to select the master dimmer level value between 000 100 for all channels SINGLE CHANNEL Chan 1 1 In Chan 1 Single Channel mod...

Page 13: ...one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order...

Page 14: ...without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sur...

Page 15: ...ut 4 wire GD 120 230 VAC 120 Amps 50 60Hz OUTPUT CAPACITY 120VAC 12 channels 1200 Watts per channel 120VAC 230VAC 12 channels 2300 Watts per channel 230VAC OUTPUT PANEL Hard wired terminal blocks OVER...

Reviews: