Setup
-8-
Nexus™ 4x1 User Manual Rev. 3
3. Setup
AC Power
AC Plug
Fuse
Replacement
The Nexus™ 4x1 has an auto-ranging power supply that works with an input voltage range of
100–240 VAC, 50/60 Hz. To determine the power requirements for the Nexus™ 4x1, refer to
the label on the product or
Technical Specifications
in this manual.
The listed current rating indicates the maximum current draw during normal operation. For
more information, download Sizing Circuit Breakers from the Chauvet website
www.chauvetprofessional.com
.
•
Always connect this product to a protected circuit with an appropriate electrical ground.
•
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
The Nexus™ 4x1 comes with a power input cord terminated with a Neutrik® powerCON®
connector on one end, and an Edison plug on the other end (U.S. market). If the power input
cord that came with the Nexus™ 4x1 has no plug, or there is the need to change the plug, use
the table below to wire a new plug.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
The fuse is a T 3.15 A, 250 V and it is located in a fuse holder next to the etherCON® power
ports. To replace the fuse, do the following:
1. Disconnect the product from the power outlet.
2. Using a flat-head screwdriver, unscrew the fuse holder cap.
3. Remove the blown fuse and replace it with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place.
5. Reconnect the power to the product.
Make sure to disconnect the power before replacing a blown fuse. Always replace the blown fuse
with a fuse of the same type and rating.