PECIFICATIONS

 

 

Dimensions and 

Weight

 

Length 

Width 

Height 

Weight 

5.5 in (140 mm) 

5.4 in (137 mm)  

4.1 in (106 mm) 

0.7 lbs (0.3 kg) 

 

 

 

 

Note: 

Dimensions in inches rounded to the nearest decimal digit

 

 

 

Power 

 

 

Input Voltage 

Range 

Voltage Selection 

12 VDC 600 mA 

100~240 V, 50/60 Hz 

Auto-ranging 

 

 

 

Parameter

 

120 V, 60 Hz 

230 V, 50 Hz 

Energy consumption 

6 W (FX 2.0/RGX 2.0) 

6 W (FX 2.0/RGX 2.0) 

8 W (RBX) 

10 W (RBX) 

Operating current (units) 

0.1A 

0.1 A 

 

 

 

Power I/O 

Input 

Output 

Cord plug 

Edison (USA) 

N/A 

 

 

 

 

Light Source

 

 

 

 

 

 

 

 

MiN Laser FX 2.0 

MiN Laser RGX 2.0

 

Type 

Power 

Wavelength 

Laser (green) 

50 mW 

532 nm 

Laser (red) 

100 mW 

650 nm 

 

 

 

 

MiN Laser RBX

 

Type 

Power 

Wavelength 

Laser (blue) 

80 mW 

450 nm 

Laser (red) 

100 mW 

650 nm 

 

 

 

 

Photo Optic

 

Parameter 

Value 

 

Coverage angle 

100

º

 

 

 

 

 

 

Thermal

 

Maximum External 

Temp. 

Cooling System 

 

104° F (40° C) 

Fan cooled 

 

 

 

 

 

Ordering

 

Product Name 

Item Code  

Item Number 

MiN™ Laser RGX 2.0 

10060415 

MINLASERRGX2.0 

MiN™ Laser FX 2.0 

10060414 

MINLASERFX2.0 

MiN™ Laser RBX 

10060477 

MINLASERRBX 

 
 

 

Summary of Contents for MinLaser FX 2.0

Page 1: ...LIGHT AVOID DIRECT EYE EXPOSURE CLASS 3R LASER PRODUCT CLASSIFIED PER EN IEC 60825 1 2007 Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No 50 dated June 24 2007 ...

Page 2: ... to shipping or concealed damage file a claim with CHAUVET within seven 7 days of receiving the merchandise Manual Conventions CHAUVET manuals use the following conventions to differentiate certain types of information from the regular text Convention Meaning Menu A key to be pressed on the product s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settin...

Page 3: ...t authorized technical assistance center Never connect this product to a dimmer pack Make sure the power cord is not crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Never carry a product from the power cord or any moving part Always use the hanging mounting bracket or the handles Always avoid direct eye exposure to the light source when this product is on Laser...

Page 4: ... which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first reading and understanding all safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters 9 8 feet above the floor on which people can stand See Proper Usage section later in this ma...

Page 5: ...MinLasers RGX 2 0 FX 2 0 RBX User Manual 5 EN Laser Safety Label Reproduction Front Rear Top Bottom ...

Page 6: ...meter 5mm at aperture Pulse Data All pulses 4 Hz 0 25 sec Divergence each beam 2 mrad Divergence total light 160 degrees Laser Power of Each Beam from Aperture 5 mW MiN Laser RBX Laser Classification Class 3R Blue Laser Medium LD InGaN 450 nm Red Laser Medium LD GaAIAs 650 nm Beam Diameter 5mm at aperture Pulse Data All pulses 4 Hz 0 25 sec Divergence each beam 2 mrad Divergence total light 160 de...

Page 7: ...s RGX 2 0 FX 2 0 RBX User Manual 7 EN 2 INTRODUCTION Product Overview Laser Output Mode Button Microphone LED Indicator Wireless Remote Receiver Cooling Fan Green Laser Dimmer RGX 2 0 FX 2 0 ONLY 12 V Power In ...

Page 8: ... a hanging clamp When rigging consider routine maintenance Please see the following notes on installation When aiming the products you may use the bracket adjustment knob s Loosen the knob s adjust to the desired angle and then tighten the knob s by turning clockwise Do not use tools for this step as it may cause damage Use the floor stand to support the product in a sitting position Proper Usage ...

Page 9: ...c A fast effects 4 Automatic B slow effects The LED indicator on the front of the product will be blue when a sound active mode is selected The LED indicator on the front of the product will be red when an automatic mode is selected Wireless Remote IR The wireless Remote IR will immediately override the MODE button No additional settings are required Cycles through auto programs Cycles through col...

Page 10: ...refully after cleaning them Do not spin the fan using compressed air because you could damage it DO NOT open this product for cleaning or servicing Returns The user must send the merchandise prepaid in the original box and with its original packing and accessories CHAUVET will not issue call tags Call CHAUVET and request a Return Merchandise Authorization RMA number before shipping the product Be ...

Page 11: ... 2 0 6 W FX 2 0 RGX 2 0 8 W RBX 10 W RBX Operating current units 0 1A 0 1 A Power I O Input Output Cord plug Edison USA N A Light Source MiN Laser FX 2 0 MiN Laser RGX 2 0 Type Power Wavelength Laser green 50 mW 532 nm Laser red 100 mW 650 nm MiN Laser RBX Type Power Wavelength Laser blue 80 mW 450 nm Laser red 100 mW 650 nm Photo Optic Parameter Value Coverage angle 100º Thermal Maximum External ...

Page 12: ...29 1115 Fax 954 929 5560 Toll free 800 762 1084 Technical Support Voice 954 929 1115 Press 4 Fax 954 756 8015 Email tech chauvetlighting com General Information Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web World Wide Web www chauvetlighting com www chauve...

Reviews: