background image

 

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

¾

 

1 x LED-PAR196 LED Splash™ 

¾

 Warranty 

Card 

¾

 Users 

Manual

Unpacking Instructions 

Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

AC Voltage Switch Example 

To determine the power requirements for a particular product, see the label affixed to the back plate 

of the product or refer to the product’s specifications chart. A product’s listed current rating is its 

average current draw under normal conditions. All fixtures must be powered directly off a switched 

circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, 

even if the rheostat or dimmer channel is used solely for a 0% to 100% 

switch. Before applying power, check that the source voltage matches the 

product’s requirement. Check the product or device carefully to make sure 

that if a voltage selection switch exists that it is set to the correct line 

voltage you will use. 

 
Warning! 

If applicable, verify that the power select switch on your unit matches the line 
voltage applied. All fixtures must be connected to circuits with a suitable Earth 
Ground.  

Safety Instructions 

 

 

 

Please keep this User Guide for future consultation. If you 
sell the unit to another user, be sure that they also receive 
this instruction booklet. 

 

Always make sure that you are connecting to the proper 
voltage and that the line voltage you are connecting to is 
not higher than that stated on decal or rear panel of the 
fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to 
rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 

 

The unit must be installed in a location with adequate 
ventilation, at least 50cm from adjacent surfaces. Be sure 
that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or 
replacing lamp or fuse and be sure to replace with same 
lamp source. 

 

Secure fixture to fastening device using a safety chain. 
Never carry the fixture solely by its head. Use its carrying 
handles. 

 

Maximum ambient temperature is Ta: 40

°

. Do not operate 

fixture at temperatures higher than this.  

 

In the event of serious operating problem, stop using the 
unit immediately. Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to 
damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the 
same type spare parts. 

 

Don’t connect the device to a dimmer pack. 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on the 
cord. 

 

Avoid direct eye exposure to lamp while it is on.  

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET. 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance? 

LED-PAR196 User Manual 

 

2008-04-02/13:33

 

Summary of Contents for LED Splash LED-PAR196

Page 1: ...LED PAR196 LED Splash USER MANUAL CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2008 04 02 13 33 ...

Page 2: ...TUP 6 POWER 6 MOUNTING 6 OPERATING INSTRUCTIONS 7 MASTER SLAVE MODE 7 Daisy Chain Connection 7 Dipswitch Options 7 DMX CONTROL MODE 8 Setting the DMX address 8 APPENDIX 9 DMX PRIMER 9 Fixture Linking 9 DMX CHANNEL VALUES 10 RETURNS PROCEDURE 10 CLAIMS 10 DMX DIPSWITCH QUICK REFERENCE CHART 11 TECHNICAL SPECIFICATIONS 12 TECHNICAL SUPPORT 12 LED PAR196 User Manual 2 2008 04 02 13 33 ...

Page 3: ... sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure the...

Page 4: ...lor change program with 10 selectable speeds 7 static colors 5 color pattern chase programs with adjustable speeds and sound active mode via LED BOSS COLORboss TM controller Up to 100 000 hour LED life span Master Slave mode OPTIONS Optional LED BOSS COLORboss TM controller Programmable Any universal DMX 512 controller DMX Channel Summary Ch 1 2 CHANNEL INTENSITY CONTROL OF 1 Red 2 Green 3 Blue 4 ...

Page 5: ...ressing DMX Connectors Switch selectable voltage Fuse Power plug Green LED DMX Signal Indicator Hanging yoke 7 LED circles are controlled individually to create an unlimited range of visible colors Red LED Power Indicator LED PAR196 User Manual 5 2008 04 02 13 33 ...

Page 6: ...y off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATIONAL BROWN Liv...

Page 7: ...ns 3 Slaves Set dipswitch 1 to the ON position and all others to the OFF position 4 You can also run the fixtures in an automatic stand alone mode by simply setting all fixtures to run as master units Daisy Chain Connection 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture ...

Page 8: ...ing a fixture using the DMX 512 control protocol than I suggest jumping to the Appendix Section and read the heading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each switch in the ON position will provide...

Page 9: ...of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 i...

Page 10: ...se for the return Be sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage ...

Page 11: ...5 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 ...

Page 12: ... Watt Quantity 196 Total Red 85 Green 51 Blue 60 FUSE Main 20mm Glass 2A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 7 ORDERING INFORMATION LED Splash LED PAR196 COLORboss LED BOSS Technical Support Address Service Dept 3000 N 29th Ct Hollywood...

Reviews: