12/31/2008 4:20 PM

 

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Merchandise Authorization Number (R MA #). 

Products returned without an RMA # will be refused. Call CHAUVET and request RMA # prior to 

shipping the fixture. Be prepared to provide the model number, serial number and a brief description 

of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from 
inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own 

discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is 

always a safe method to use. 

Note: 

If you are given an RMA #, please include the following information on a piece of 

paper inside the box: 

1) 

Your name 

2) 

Your address 

3) 

Your phone number 

4) 

The RMA # 

5) 

A brief description of the symptoms 

Claims 

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 

reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and 

submit claims with the shipper in the event that a fixture is damaged due to shipping.  Any other claim 

for items such as missing component/part, damage not related to shipping, and concealed damage, 

must be made within seven (7) days of receiving merchandise. 

 

Technical Specifications 

WEIGHT & DIMENSIONS 

Length .................................................................................................................................. 3.2 in (82 mm) 
Width .................................................................................................................................... 3.9 in (99 mm) 
Height ................................................................................................................................... 3.4 in (87 mm) 
Weight .................................................................................................................................. 0.7 lbs (0.3 kg) 
 

POWER 

Switch-selectable power settings .......................................................................... 100V-240VAC 50/60Hz 
Power Consumption ........................................................................................ 2.4W (0.03A) max @ 120V 
Inrush Power ........................................................................................................................ (0.3A) @ 120V 

 
LIGHT SOURCE 

LED .............................................................................................  1x 750mA (1 White 8,500 K) 50,000hrs 

 
PHOTO OPTIC 

Beam Angle .............................................................................................................................................. 9° 
 

THERMAL 

Maximum ambient temperature .............................................................................................104°F (40°C) 

 
ORDERING INFORMATION 

LED Pinspot .......................................................................................................................... LEDPINSPOT 
 

WARRANTY INFORMATION 

Warranty.................................................................................................................. 1-year limited warranty 

Summary of Contents for LED Pinspot

Page 1: ... Pinspot User Manual 1 12 31 2008 4 20 PM LED Pinspot USER MANUAL Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master Slave Autoswitching Transformer Replaceable Fuse User Serviceable Duty Cycle ...

Page 2: ...included 1 x LED Pinspot Warranty Card User Manual Unpacking Instructions Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling ...

Page 3: ...be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Warning All fixtures must be connected to circuits with a suitable Earth Ground Contact Us World Wide General Information CHAUVET 3000 North 29 th Court Hollywood FL 33020 voice 954 929 1115 fax 954 929 5560 toll...

Page 4: ...arrying handles Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type s...

Page 5: ...LED Pinspot User Manual 5 12 31 2008 4 20 PM Product Overview Hanging bracket Bracket adjustment knob Safety eyebolt Power in ...

Page 6: ...thway Mount the fixture using a suitable C or O type clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables must always be used Never mount in places where the fixture will be exposed to rai...

Page 7: ...month Dust build up reduces light output performance and can cause overheating This can lead to reduced lamp life and increased mechanical wear Be sure to power off fixture before conducting maintenance Unplug fixture from power Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components Clean all glass when the fixture is cold with a mild sol...

Page 8: ...per inside the box 1 Your name 2 Your address 3 Your phone number 4 The RMA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shippi...

Reviews: