background image

 
 
 
 

Page 10 of 19 

Geyser P4. User Manual Rev. 2 

Alternate Inverted 

Truss Mounting 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

With inverted mounting, avoid spillage of the fog fluid by setting the fluid tank in 
an upright position. Be sure to use a safety cable for both the Geyser P4 and the 
fluid tank when rigging in this manner.

 

 

 

Safety Cable for 

the Fluid Tank 

Mounting Clamps 

(works with CLP-15 or 

CLP-15N clamp from 

Chauvet) 

TRUSST® 

(or other elevated 

platform or truss)

 

The Fluid Tank 

in an upright 

position

 

Safety Cable

 

Overhead Mounting – Downward Fog Jet 

Summary of Contents for GEYSER P4

Page 1: ...User Manual ...

Page 2: ... Orientation 8 Rigging 8 Tank Inversion Steps for Inverted Mounting 11 4 Operation 12 Control Panel Operation 12 Menu Map 12 DMX Personality and Starting Address 12 DMX Linking 12 Configuration DMX 12 Configuration Standalone 14 Programmable Color Selection MANUAL 14 Programmable Color Selection Wireless Remote Control 14 Wireless Remote Control 14 5 Technical Information 15 Fogger Maintenance 15 ...

Page 3: ...or Important installation or configuration information The product may not function correctly if this information is not used Useful information Disclaimer Chauvet believes that the information contained in this manual is accurate in all respects However Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss damage or disruption caused by any e...

Page 4: ...the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots on the product s housing are blocked Make sure there is adequate fog fluid in the machine to prevent pump and heater damage ...

Page 5: ... 5 of 19 2 INTRODUCTION Overview LED Display Control Buttons Nozzle and LEDs Fluid Tank On Off Switch Safety Eye Loop Remote Control Receiver Port Fuse Holder Power In Handles Manual Fog Button DMX In Out Safety Eye Loop Fluid Line In ...

Page 6: ...Page 6 of 19 Geyser P4 User Manual Rev 2 Dimensions 7 in 180 mm 10 2 in 260 mm 13 4 in 340 mm 2 39 in 60 8 mm ...

Page 7: ...ropriate electrical ground to avoid the risk of electrocution or fire Never connect the product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 100 switch Fuse Replacement Disconnect the product from power before replacing the fuse 1 Disconnect the product from power 2 Wedge the tip of a flat head screwdriver into the slot of the fuse hol...

Page 8: ...the product s weight see the Technical Specifications When mounting the product overhead always use a safety cable Mount the product securely to a rigging point such as an elevated platform or a truss When rigging the product onto a truss you should use mounting clamps of appropriate weight capacity Two threaded mounting holes size M12 are on the bottom of the product which are appropriate for thi...

Page 9: ...t The dimensions shown for the mounting hole positions are included here to aid in installation Floor Mounting Floor Mounting Vertical Fog Output Floor Mounting Horizontal Fog Output 8 5 in 216 mm 7 in 178 mm Bottom Panel View Threaded Mounting Holes size M12 ...

Page 10: ... tank in an upright position Be sure to use a safety cable for both the Geyser P4 and the fluid tank when rigging in this manner Safety Cable for the Fluid Tank Mounting Clamps works with CLP 15 or CLP 15N clamp from Chauvet TRUSST or other elevated platform or truss The Fluid Tank in an upright position Safety Cable Overhead Mounting Downward Fog Jet ...

Page 11: ...tle lock to take out the tank 3 Turn the fog machine upside down remove the screws and set aside to take off the removable plate 4 Attach the removable plate to the opposite side and secure the tank with the bottle lock 5 Secure both the bottom plate and tank cover with the screws Actual product may vary slightly from photo Bottle Lock Removable Plate ...

Page 12: ...ely DMX Personality and Starting Address When selecting a starting DMX address always consider the number of DMX channels the selected DMX mode uses If you choose a starting address that is too high you could restrict the access to some of the product s channels The Geyser P4 uses up to 10 DMX channels in a 10CH DMX mode which defines the highest configurable address to 503 If you are not familiar...

Page 13: ... 6 058 ó 065 Color Macro 7 066 ó 073 Color Macro 8 074 ó 081 Color Macro 9 082 ó 089 Color Macro 10 090 ó 097 Color Macro 11 098 ó 105 Color Macro 12 106 ó 113 Color Macro 13 114 ó 121 Color Macro 14 122 ó 129 Color Macro 15 130 ó 137 Color Macro 16 138 ó 145 Color Macro 17 146 ó 153 Color Macro 18 154 ó 161 Color Macro 19 162 ó 169 Color Macro 20 170 ó 177 Color Macro 21 178 ó 185 Color Macro 22 ...

Page 14: ...using the wireless remote control follow the instructions below 1 Press MENU repeatedly until CH 1 CH 4 shows on the display Select CH 1 CH 2 CH 3 or CH 4 to choose that color program Note The color program numbers correspond with the numbered buttons on the wireless transmitter 2 Press ENTER 3 Use UP or DOWN to select P1 1 P1 32 to choose one of 32 preset color programs 4 Press ENTER 5 Repeat ste...

Page 15: ... almost empty Do not allow the pump to run dry 6 Refill with fog fluid Run the machine briefly to clear any cleaning solution from the pump and heater Fog Cleaner Quart FCQ was specifically developed by Chauvet to clean your Geyser P4 Make sure you use FCQ regularly no longer than 90 days between cleanings to increase the life of your fogger Storage Maintenance Before storing the fogger run FCQ th...

Page 16: ...er cord Blown fuse Replace blown fuse with a good one of the same type and rating Internal problem Send product for repair Product does not output fog Addr or HEAT No fluid Turn the product off and replenish the fog fluid use only CHAUVET water based fog fluid Heater or pump clogged Clean thoroughly with CHAUVET FCQ For full instructions see Fogger Maintenance Refill with CHAUVET water based fog f...

Page 17: ... 6 A 5 6 A Fuse F 13 A 250 V F 13 A 250 V Power I O US Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison US Local plug Light Source Type Power Lifespan LED 7 3 W 50 000 hours Parameter Illuminance 485 lux 2 m Color Quantity Current RGBA UV 4 2 5 A Operation Capacity Consumption Heat up Time Tank Capacity Fluid Consumption 2 min 2 5 l 0 7 gal...

Page 18: ... Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return You must send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet will refuse any product returned with...

Page 19: ... Wide Web www chauvetlighting eu General Information Chauvet Europe Ltd Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO General Information Chauvet Mexico Address Av de las Partidas 34 3B Zona Industrial Lerma Lerma Edo de Me...