COLORdash
™ Par
User Manual
15
9/4/2008 12:09 PM
MENU
UP
DOWN
ENTER
Setting the DMX address
Each fixture requires a "start address" from 1 to 512. A fixture requiring one or more channels for
control begins to read the data on the channel indicated by the start address. For example, a fixture
that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would
read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose start addresses so that the
channels used do not overlap and note the start address selected for future reference. The
COLORado™ Panel uses up to 9 channels of DMX. If this is your first time using DMX, we
recommend reading the DMX Primer in the Appendix Section.
Control Panel Functions
All fixture functions and settings are accessible via the built-in control panel interface.
B
UTTON
F
UNCTION
MENU
Exits from the current menu or function
ENTER
Enables the currently displayed menu or sets the currently selected value in to the
selected function
UP
Navigates upwards through the menu list and increases the numeric value when in
a function
DOWN
Navigates downwards through the menu list and decreases the numeric value when
in a function
Password Menu Lockout
The
COLORdash™ PAR has a
password lock-out feature. This can be enabled/disabled by using the Control
Panel.
Note:
This feature uses a default, non-changeable, password of up + down + up + down. After
30 seconds of inactivity, the lockout will automatically engage once it has been enabled.