COLORdash™ Block User Manual
11
6/19/2009 4:54 PM
This drawing
provides a general
illustration of the
DMX input/output
panel of a lighting
fixture.
Universal DMX
Controller
Continue the link
Often, the setup for Master-Slave
and Standalone operation
requires that the first fixture in the
chain be initialized for this
purpose via settings in the control
panel. Secondly, the fixtures that
follow may also require a slave
setting. Please consult the
“Operating Instructions” section in
this manual for complete
instructions for this type of setup
and configuration.
Master
Slave
Slave
3-Pin to 5-Pin Conversion Chart
If you use a controller with a 5-pin DMX output connector, you will need to use a 5-pin to 3-pin
adapter. CHAUVET Model No: DMX5M, or DMX5F.
The chart below details a proper cable conversion:
3-P
IN TO
5-P
IN
C
ONVERSION
C
HART
Conductor
3-Pin Female (Output)
5-Pin Male (Input)
Ground/Shield
Pin 1
Pin 1
Data ( - ) signal
Pin 2
Pin 2
Data ( + ) signal
Pin 3
Pin 3
Not used
Pin 4
Not used
Pin 5
Setting up a DMX Serial Data Link
1. Connect the (male) 3-pin connector side of the
DMX cable to the output (female) 3-pin
connector of the controller.
2. Connect the end of the cable coming from the
controller which will have a (female) 3-pin
connector to the input connector of the next
fixture consisting of a (male) 3-pin connector.
3. Then, proceed to connect from the output as
stated above to the input of the following fixture
and so on.
CHAUVET Certified DMX Data Cables
Order Code
Description
DMX1.5
DMX Cable 1.5 m/4.9 ft
DMX4.5
DMX Cable 4.5 m/14.8 ft
DMX10
DMX Cable 10 m/32.8 ft
Master/Slave Fixture Linking
1. Connect the (male) 3-pin connector side of the DMX cable to the output (female) 3-pin connector
of the first fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3-pin
connector to the input connector of the next fixture consisting of a (male) 3-pin connector. Then,
proceed to connect from the output as stated above to the input of the following fixture and so on.