CH-302A User Manual 

3

 

8/28/2006/17:57  

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

¾

 

1 x Cosmos 2.0 (CH-302A), (2) 
Dome covers, (2) Disc covers 

¾

 

Power cord with plug 

¾

 

(24) clear lenses, (74) colored 
lenses 

¾

 

(2) x 64514 300w lamps 

¾

 Warranty 

Card

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of 

the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average 

current draw under normal conditions. All fixtures must be powered directly off a switched circuit and 

cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer 

channel is used solely for a 0% to 100% switch. Before applying power to a 

fixture, check that the source voltage matches the fixture’s requirement. 

Check the fixture or device carefully to make sure that if a voltage selection 

switch exists that it is set to the correct line voltage you will use. 

Warning! 

Verify that the power select switch on your unit matches the 
line voltage applied. All fixtures must be connected to circuits 
with a suitable Earth Ground.  

 

Safety Instructions 

 

Please keep this User Guide for future consultation. If you 
sell the unit to another user, be sure that they also receive 
this instruction booklet. 

 

Always make sure that you are connecting to the proper 
voltage and that the line voltage you are connecting to is 
not higher than that stated on decal or rear panel of the 
fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to 
rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 

 

The unit must be installed in a location with adequate 
ventilation, at least 50cm from adjacent surfaces. Be sure 
that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or 
replacing lamp or fuse and be sure to replace with same 
lamp source. 

 

Secure fixture to fastening device using a safety chain. 
Never carry the fixture solely by its head. Use its carrying 
handles. 

 

Maximum ambient temperature is Ta: 40

°

. Do not operate 

fixture at temperatures higher than this.  

 

In the event of serious operating problem, stop using the 
unit immediately. Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to 
damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the 
same type spare parts. 

 

Don’t connect the device to a dimmer pack. 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on the 
cord. 

 

Avoid direct eye exposure to lamp while it is on.  

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET. 

Figure 1 - AC Voltage Switch 

Not all fixtures have a voltage 
select switch. Please be sure to 
connect to the proper voltage. 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance? 

 

Summary of Contents for CH-302A

Page 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com CH 302A Cosmos 2 0 USER MANUAL ...

Page 2: ...DUCT OVERVIEW H4 HSETUP H5 HLAMP H5 HLamp Installation H5 HPOWER H5 HMOUNTING H5 HOPERATING INSTRUCTIONS H6 HGeneral operation H6 HFlash On Off Rotary knob H6 HRotation rotary knob H6 HCON EF2 Wired Remote Optional H6 HAPPENDIX H7 HGENERAL MAINTENANCE H7 HRETURNS PROCEDURE H7 HCLAIMS H7 HGENERAL TROUBLESHOOTING H8 HLAMP IN SERIES WIRING DRAWING FOR 230V OPERATION H9 HTECHNICAL SPECIFICATIONS H9 ...

Page 3: ...ion If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Mak...

Page 4: ...4 interchangeable colored lens installed on dome 24 additional clear lens included centered rigging point for single clamp mount easy lamp access on board control features flash full on switch flash speed knob rotation speed knob optional wired remote 360 rotation on both axis wide area light dispersion Product Overview Power input Dome fixture cover Disc fixture cover 5 pin XLR to remote controll...

Page 5: ...the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions All fixtu...

Page 6: ...smos 2 0 to flash intermittently The rate of the flash can be adjusted using the FLASH rotary knob ROTATION ROTARY KNOB The ROTATION rotary knob affects the speed of the mechanical rotations on the Cosmos 2 0 CON EF2 WIRED REMOTE OPTIONAL The CON EF2 provides an extension to the same on board controls on the Cosmos 2 0 This optional controller would provide the user the ability to shift from fast ...

Page 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Page 8: ... device s fuse internal and or external 9 9 9 Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life 9 Motor movements are jerky or jumpy Possible bad motor driver or sensors Check polarity switch on controller 9 9 Moves slow Check 220 110v switch for proper setting 9 No flash Re install bulb may have shifted in shipping 9 No light output Check slip ...

Page 9: ...mps in series is the most effective and economical method Tests have shown that the lamp will hold much longer than their 230V counter parts Technical Specifications WEIGHT DIMENSIONS Length 216 mm 8 5 in Width 432 mm 17 in Height 356 mm 14 in Weight 5 67 Kg 12 5 lbs POWER Switch selectable power setting 115V 60 Hz or 230V 50 Hz AC input 3 prong IEC 60320 C14 LAMPS 64514 x 2 115V 300 hr 300W THERM...

Reviews: