CH-302A User Manual
5
8/28/2006/17:57
Slide switch up or down
depending on your line voltage.
Hanging Clamp
Clamp sold separately!
S
ETUP
Lamp
You will need to install a lamp prior to the initial operation of the fixture. Two 64514 halogen lamps
are included.
Warning!
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp
with alcohol and wipe it with a lint free cloth before installation.
L A M P I N S T A L L A T I O N
1)
Remove the 3 screws on both of the fixture lamp covers.
2)
If replacing the lamp, remove old lamp first.
3)
Reach in with the lamp out of the retaining cage.
4)
Detach the lamp from the lamp socket and replace.
5)
Replace lamp face plate, align the screw holes and fasten the
screws.
6)
No lamp alignment is necessary for this fixture since the lamp
is already optimized inside the reflector.
Power
Your product is equipped with switch-selectable AC power
setting.
Warning!
Verify that the power select switch on your unit matches the
line voltage applied. All fixtures must be connected to
circuits with a suitable Earth Ground.
•
To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or
refer to the fixture’s specifications chart.
•
A fixture’s listed current rating is its average current draw under normal conditions.
•
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or
dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
•
Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.
•
All fixtures must be connected to circuits with a suitable Earth Ground.
Mounting
It is important never to obstruct the fan or vents pathway. Mount the fixture
using, a suitable “C” or “O” type clamp. Ideally, this fixture is best orientated
with the spinning spheres on the bottom and the base of the unit on top.
•
When selecting installation location, take into consideration lamp replacement access
and routine maintenance.
•
Safety cables should always be used.
•
Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or
restricted ventilation.