background image

 

CH-302A User Manual 

5

 

8/28/2006/17:57  

Slide switch up or down 
depending on your line voltage. 

Hanging Clamp

Clamp sold separately!

S

ETUP

 

Lamp 

You will need to install a lamp prior to the initial operation of the fixture. Two 64514 halogen lamps 

are included.  

Warning! 

When replacing the lamp, please wait 15 minutes after powering down to allow the 
unit to cool down! Always disconnect from main power prior to lamp replacement. 

Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp 

with alcohol and wipe it with a lint free cloth before installation. 

L A M P   I N S T A L L A T I O N  

1) 

Remove the 3 screws on both of the fixture lamp covers. 

2) 

If replacing the lamp, remove old lamp first. 

3) 

Reach in with the lamp out of the retaining cage. 

4) 

Detach the lamp from the lamp socket and replace. 

5) 

Replace lamp face plate, align the screw holes and fasten the 
screws. 

6) 

No lamp alignment is necessary for this fixture since the lamp 
is already optimized inside the reflector. 

Power 

Your product is equipped with switch-selectable AC power 

setting.  

Warning! 

Verify that the power select switch on your unit matches the 
line voltage applied. All fixtures must be connected to 
circuits with a suitable Earth Ground.  
 

 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or 
refer to the fixture’s specifications chart.  

 

A fixture’s listed current rating is its average current draw under normal conditions.  

 

All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or 
dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.  

 

Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.  

 

All fixtures must be connected to circuits with a suitable Earth Ground.  

Mounting 

It is important never to obstruct the fan or vents pathway. Mount the fixture 

using, a suitable “C” or “O” type clamp. Ideally, this fixture is best orientated 

with the spinning spheres on the bottom and the base of the unit on top.  

 

When selecting installation location, take into consideration lamp replacement access 
and routine maintenance.  

 

Safety cables should always be used.  

 

Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or 
restricted ventilation.

 

 

Summary of Contents for CH-302A

Page 1: ...CHAUVET 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com CH 302A Cosmos 2 0 USER MANUAL ...

Page 2: ...DUCT OVERVIEW H4 HSETUP H5 HLAMP H5 HLamp Installation H5 HPOWER H5 HMOUNTING H5 HOPERATING INSTRUCTIONS H6 HGeneral operation H6 HFlash On Off Rotary knob H6 HRotation rotary knob H6 HCON EF2 Wired Remote Optional H6 HAPPENDIX H7 HGENERAL MAINTENANCE H7 HRETURNS PROCEDURE H7 HCLAIMS H7 HGENERAL TROUBLESHOOTING H8 HLAMP IN SERIES WIRING DRAWING FOR 230V OPERATION H9 HTECHNICAL SPECIFICATIONS H9 ...

Page 3: ...ion If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Mak...

Page 4: ...4 interchangeable colored lens installed on dome 24 additional clear lens included centered rigging point for single clamp mount easy lamp access on board control features flash full on switch flash speed knob rotation speed knob optional wired remote 360 rotation on both axis wide area light dispersion Product Overview Power input Dome fixture cover Disc fixture cover 5 pin XLR to remote controll...

Page 5: ...the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions All fixtu...

Page 6: ...smos 2 0 to flash intermittently The rate of the flash can be adjusted using the FLASH rotary knob ROTATION ROTARY KNOB The ROTATION rotary knob affects the speed of the mechanical rotations on the Cosmos 2 0 CON EF2 WIRED REMOTE OPTIONAL The CON EF2 provides an extension to the same on board controls on the Cosmos 2 0 This optional controller would provide the user the ability to shift from fast ...

Page 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Page 8: ... device s fuse internal and or external 9 9 9 Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life 9 Motor movements are jerky or jumpy Possible bad motor driver or sensors Check polarity switch on controller 9 9 Moves slow Check 220 110v switch for proper setting 9 No flash Re install bulb may have shifted in shipping 9 No light output Check slip ...

Page 9: ...mps in series is the most effective and economical method Tests have shown that the lamp will hold much longer than their 230V counter parts Technical Specifications WEIGHT DIMENSIONS Length 216 mm 8 5 in Width 432 mm 17 in Height 356 mm 14 in Weight 5 67 Kg 12 5 lbs POWER Switch selectable power setting 115V 60 Hz or 230V 50 Hz AC input 3 prong IEC 60320 C14 LAMPS 64514 x 2 115V 300 hr 300W THERM...