Chassis Plans CPC1-C17, -C19 Technical Reference
Appendix A – Display Serial Control Programming
Page 56
Select) ”?”
Blue Mono/
Red Mono/
GreenMono/
“4” – Blue Mono
“5” – Red Mono
“6” – Green Mono
PIP Swap
0xe3
Swap Main and PIP source
"0" - Fail.
"1" - Successful.
Backlight D/A /
PWM
0xe5
“0” | “1” |
“R” | “r”
”?”
Set : PWM or D/A
Reset
Query
“0” – PWM
“1” – D/A
Backlight PWM
Frequency
0xe6,
nnn | “+” | “-” |
“R” | “r” |
“?”
Set Backlight PWM Frequency =
value/increment/decrement
Reset
Query
+/- 20Hz
Value
100Hz : “0”,”6”,”4”
120Hz : “0”,”7”,”8”
140Hz : “0”,”8”,”C”
160Hz : “0”,”A”,”0”
180Hz : “0”,”B”,”4”’
200Hz : “0”,”C”,”8”
220Hz : “0”,”D”,”C”
240Hz : “0”,”F”,”0”
260Hz : “1”,”0”,”4”
280Hz : “1”,”1”,”8”
300Hz : “1”,”2”,”C”
320Hz : “1”,”4”,”0”
340Hz : “1”,”5”,”4”
360Hz : “1”,”6”,”8”
380Hz : “1”,”7”,”C”
400Hz : “1”,”9”,”0”
420Hz : “1”,”A”,”4”
440Hz : “1”,”B”,”8”
Backlight Invert
0xe7
“0” | “1” |
“R” | “r”
”?”
Set On or Off
Reset
Query
“0” – Off
“1” – On
Red Offset for
selected colour
temperature
0xe8,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the Offset of the red channel
for the selected colour temp. =
value/increment/decrement
Reset
Query
Red Offset for selected colour
temperature.
Green Offset for
selected colour
temperature
0xe9,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the Offset of the green
channel for the selected colour
temp. =
value/increment/decrement
Reset
Query
Green Offset for selected colour
temperature.
Blue Offset for
selected colour
temperature
0xea,
nn | “+” | “-” |
“r” | “R” |
“?”
Set the Offset of the blue
channel for the selected colour
temp. =
value/increment/decrement
Reset
Query
Blue Offset for selected colour
temperature.
PIP Window Auto
Off
“0xee”, “0x41”
“0” |”1”
“?”
Auto Off / Auto On
Query
“0”- Off
“1”- On
Custom Sizing
0xef,
“0” | “1” | “2”
”?”
Custom sizing selection :
Overscan / Normal / Custom
Query
“0” – Overscan
“1” – Custom
“2” – Normal