Trifecta 2K
P
RESSURE
/D
IFFERENTIAL
P
RESSURE
T
RANSMITTERS
There are five transmitters in the T
RIFECTA
system. Two of the transmitters are measuring
differential pressure of each of the Laser-Cyls. This is to provide a measure of liquid level. The
other three transmitters are pressure transmitters. The five transmitters are used to provide
pressure and liquid level information to the PLC for controlling purposes. T
ABLE
6 lists the
specifications for the transmitters used.
17
L
ASER
-C
YL
P
RESSURE
S
AFETY
D
EVICES
Each Laser-Cyl in this system has its own pressure relief safety system. They each have a
relief valve and a rupture disc. T
ABLE
7 lists the specifications on these devices.
L
INE
R
ELIEF
V
ALVES
The system has many line relief valves. These relief valves protect against the accidental
closing of two valves with trapped liquid between them. The line relief valves are installed on
“candy-canes” to help keep the valve at warmer temperatures. T
ABLE
8 lists the specifications of
the line relief valves used.
T
ABLE
6 - Transmitters
Transmitter Type
Service
Span
Output
Chart, Inc.
Part Number
Differential Pressure
Inert
0-100” WC (0-254 cm)
4-20 mA
11043751
Pressure
Inert
0-500 psig (0-34.5 bar)
4-20 mA
11043743
Part
Size
Set Pressure
Chart, Inc. Part Number
Relief Valve
½” MPT (1.3 cm)
500 psig (34.5 bar)
11030264
Rupture Disc
¼” MPT (.7 cm)
700 psig (48.3 bar)
11055525
T
ABLE
7 - Pressure Safety Devices
T
ABLE
8 - Line Relief Valves
Valve Manufacturer
Size
Set Pressure
Chart, Inc. Part Number
Rego
¼” MPT (.7 cm)
550 psig (37.9 bar)
1812702
T
ABLE
5 - Solenoid Valve Repair Kits
Repair Kit
Chart, Inc. Part Number
Solenoid Coil (120 vac)
10963071
Piston Assembly
10963062
Gasket
10963100
If the whole valve is not required, there are repair kits available for various parts of the valve.
T
ABLE
5 lists the available repair kits for these valves.
Summary of Contents for TRIFECTA 2K
Page 2: ...Trifecta 2K ...