background image

Issue A

* These items are not shown on the drawing.

To obtain spare parts please contact your local stockist giving Model, Part

No. and Description. In case of difficulty contact the manufacturer at the

address shown.

This drawing is for identification purposes only.

3

4

5

6

7

8

10

14

10

13

15

20

18

17

19

21

22

23

24

25

26

27

28

29

30

31

32

33

37

38

39

40

42

43

44

45

46

48

49

50

34

35

12

11

47

16

36

36

41

14

ISLAND IIIB PARTS LIST

®

charnwood

I S L A N D

®

charnwood

BISHOPS   WAY,   NEWPORT,   ISLE   OF   WIGHT     PO30   5WS,   UNITED   KINGDOM

T: + 4 4 ( 0 ) 19 8 3 5 37 7 9 9 • F : + 4 4 ( 0 ) 19 8 3 5 37 7 8 8 • S PA R E S @ C H A R N WO O D . C O M • W W W. C H A R N WO O D . C O M

charnwood

Item

Part No.

Description

1*

008/CY40S

Door Seal Set Inc. Adhesive

2*

008/FW29

Door Seal Adhesive

3

002/CG20

Bottom Grate Bar

4

002/CG20S12

Set of Grate Bars (12)

5

010/CY13L

Side Fire Plate L.H.

6

010/CY13R

Side Fire Plate R.H.

7

010/CY16

Back Fire Plate

8

006/CY18

Glass

9*

008/AY45

Glass Seal

10

004/KV23

Glass Retainer

11

004/ST008

Tabbed Locking Washer

12

008/FW015

M12 double coil spring

13

011/DS29S

Set of Fire Bricks (4)

14

008/FW48

Thermostat

15

010/DS31

Throat Plate

16

010/DS32

Front Throatplate

17

012/CY33

Mover Bar

18

002/CY30

Carrier Bar

19

012/AY13

Idler Rod

20

012/AY15

Riddler Rod

21

004/CY17L

Ashpan L.H.

22

004/CY17R

Ashpan R.H.

23

002/CY07C

Front Fence Island 3

24

008/KV16

R.H. Door Handle

25

002/AY14

Door Catch Cam

26

008/KV13

L.H. Door Knob

27

008/BW39/S

Hinge Pin Set (4 per set)

28

002/PY24

Hinge Post

29

008/BW50

Thermostat Knob

30

010/AY34

Riddling/Ashpan Tool

31

002/AY27

Riddler Knob

32

004/DS09

Air Bypass Slide

33

008/FV49

Thermostat Flap

34

012/FW34

Scraper Tool

35

002/CY08C

Deepening Bar

36

011/DS33S

Set of Throatplate Bricks

37

004/CS16

Thermostat Rod

38

004/CS18

Thernostat Connector Tube

39

008/DS12

Thermostat Box Gasket

40

010/DS20

Thermostat Box

41

004/DS35

Brick Fixing Clip

42

002/CY01

Left Hand Door

43

002/CY02

Right Hand Door

44

001/DS10

Firebox (Island IIIB)

45

010/CY37

Blanking Plate

46

010/CY61

Clamping Plate

47

002/CY45

Flue Collar

48

010/CY36

Flue Spacer Ring

49

012/DS11

Serial No. Label

50

010/CY34

Vert. Rear Flue Connector (Opt'l Extra)

51*

010/BW51

Ash Carrier (Optional Extra)

52*

008/TH02/L

Low level pipe thermostat (Opt'l Extra)

Item

Part No.

Description

Summary of Contents for Island III

Page 1: ...Operating Installation Instructions I S L A N D charnwood ...

Page 2: ......

Page 3: ...e flueway cleaning Chimney Sweeping Trouble Shooting If you need any Further Help Health Safety Precautions Chimney Hearth Fire Surround Connection to Flues Soot Doors Thermostat Dimensions 4 4 4 5 5 5 5 5 6 6 6 6 7 8 9 9 9 12 12 12 13 INSTALLATION INSTRUCTIONS Lighting Central Heating System System Controls Pre Lighting Check Commissioning Parts Lists Certification 4 10 11 12 12 14 15 I S L A N D...

Page 4: ... minimum effort If any operation such as riddling the grate or opening and closing the doors begins to require extra force then the cause must be investigated and corrected to prevent damage being caused to the stove Remember that the stove will be hot and is made from hard materials ensure that you have a good balance before operating the fire When using the stove in situations where children age...

Page 5: ...ct with the underside of the grate as this will seriously damage the grate bars The ashpan is handled using the tool provided Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins To make ash removal easier there is a special Charnwood ash carrier available This may be purchased from your supplier or in case of difficulty from ourselves For correct firing w...

Page 6: ... Cleaning Cleaning the Glass hob cleaner Some deposits on the glass may be burnt off simply by running the fire at a fast rate for a few minutes Do not use abrasive cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure Aerosol spray cleaners should not be used near the appliance whilst it is under fire If the fire is going to be out of use for a ...

Page 7: ...btained Keeping the glass clean requires a certain amount of experimentation due to the differences in the draw of different chimneys The following points should be noted and with a little care should enable the glass to be kept clean in most situations a The airwash relies on a supply of heated air to keep the glass clean therefore when lighting the stove allow the firebed to become well establis...

Page 8: ...hat it is not distorted c the door seals are in good condition d If the hot water goes cold when the pump is turned on or if some radiators are hotter than others then the system may need balancing the pump may be pumping the water too quickly around the system Fire blazing out of control Over Firing Freezing Lack of Heat To Radiators Hot Water or the radiators may need bleeding Please ask your in...

Page 9: ...he hearth must be at least 12mm 0 5inches thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state he chimney must not be less than 175 mm 7 inches internal diameter or 175 x 175mm internal square If an existing chimney is to be used it must be swept and checked it must be in good condition free from ...

Page 10: ...d corrosion a suitable inhibitor should be used The system must be correctly vented as shown in Figs 5 and 6 The height differential between the header tank and the appliance must not exceed 15 2 metres 50 feet If all four boiler tappings are used then if possible diagonal pairs should be connected for domestic hot water and central heating Where a common return is used an injector tee must be inc...

Page 11: ...Radiators may be either manually or thermostatically controlled These controls will all work in conjunction with the thermostat on the appliance and the low limit pipe thermostat We recommend fitting a pipe thermostat onto the gravity return to act as a low limit thermostat This should be wired into the mains supply to the pump so that if the gravity return temperature drops below 45º C then the p...

Page 12: ...MOSTAT With the control knob at the minimum setting the flap should be just closed as shown in Fig 13 To adjust the distance slacken the locking nut and adjust as necessary When set correctly re tighten the locking nut Ensure that the flap opens and closes freely as the knob is turned and that the opening is completely covered when the flap is closed Beforeinitiallightingthefollowingpoints shouldb...

Page 13: ...Flue Outlet To Suit 175mm 7 Flue Pipe 196 830 185 603 458 726 488 133 754 780 738 95 714 ISLAND IIIB DIMENSIONS charnwood I S L A N D 13 ...

Page 14: ...DS29S Set of Fire Bricks 4 14 008 FW48 Thermostat 15 010 DS31 Throat Plate 16 010 DS32 Front Throatplate 17 012 CY33 Mover Bar 18 002 CY30 Carrier Bar 19 012 AY13 Idler Rod 20 012 AY15 Riddler Rod 21 004 CY17L Ashpan L H 22 004 CY17R Ashpan R H 23 002 CY07C Front Fence Island 3 24 008 KV16 R H Door Handle 25 002 AY14 Door Catch Cam 26 008 KV13 L H Door Knob 27 008 BW39 S Hinge Pin Set 4 per set 28...

Page 15: ... WELLS SONS LTD EN13240 2001 ROOMHEATERS BOILER FIRED BY WOOD FUEL EC certificate of conformity no Maximum operating pressure Fuel types Minimum distance to combustible materials Side Rear Emission of CO in flue gases Flue gas temperature Space heating output Water heating output Energy efficiency DS50 CPD 2007 1 5 bar 200mm 120mm 0 67 354 C 9 0kW 9 0kW 73 3 Wood Logs ...

Page 16: ... i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 44 0 1983 537777 F 44 0 1983 537788 CHARNWOOD AJWELLS CO UK WWW CHARNWOOD COM charnwood y o u r p re m i e r d e a l e r REV ISLAND IIIB 03 09 ...