background image

just one control to be used. The balance between primary and

secondary air for particular flue conditions is pre-set using the sliding

control mounted on the thermostat box beneath the stove. Once set

this should not need to be adjusted.

When burning wood, ash should be allowed to build up and only

riddled when the ash begins to cover the slots in the rear fireplate.

The fire should be riddled with the doors shut (see Fig. 2.) Place the

tool onto the riddling lever and rotate between the 1 o'clock and 3

o'clock positions several times. Too much riddling can result in

emptying unburnt fuel into the ashpan and should therefore be

avoided.  After riddling, the grate should be put back into the open

or closed position as required (the tool should be in the 1 o'clock

position for open grate or in the 5 o'clock position for closed grate).

Keep the firebox well filled but do not overfill to prevent fuel from

spilling over the top of the front fire bar. Logs should be evenly

distributed, filling  the firebed to give the most pleasing flame pattern

Care should be taken especially when burning wood that fuel does

not project over the front fire bar or damage to the glass may be

caused when the doors are closed, it can also cause the glass to black

up . Maximium filling height is such that logs cannot fall from the fire

when the doors are opened. Liquid fuels are not to be used on this

appliance.

The ashpan should be emptied regularly before it becomes too full.

Never allow the ash to accumulate in the ashpan so that it comes in

contact with the underside of the grate as this will seriously damage

the grate bars. The ashpan is handled using the tool provided. Care

should be taken to ensure that ash is cool before emptying it into

plastic liners or bins.

To make ash removal easier there is a special Charnwood ash carrier

available. This may be purchased from your supplier or, in case of

difficulty, from ourselves.

For correct firing we recommend the use of a stove pipe

thermometer which may be purchased from your supplier or from

ourselves.

RIDDLING

REFUELLING

ASH CLEARANCE

Open P

osition

Closed

Position

Riddle

Fig. 2. Multifuel Grate

the fuel is well ignited then load with fuel. Once the fire is up to

temperature the airwash system will begin to work, so allow the fire

to become hot before adjusting thethermostat to the required

setting.

On initial lighting, the stove may smoke and give off an odour as the

silicon paint with which the firebox is painted reacts to the heat. This

is normal and will cease after a short time, but meanwhile the room

should be kept well ventilated.

At first only light a small fire and burn it slowly for two hours to allow

any residual moisture in the bricks to evaporate.

When relighting the stove, riddle slightly and then empty the ashpan.

The fire is controlled by the water temperature thermostat. The

water temperature is set by the control knob shown in Fig. 1. Turn

the knob clockwise to increase the water temperature or anti-

clockwise to decrease.

This thermostat controls both primary and secondary air, enabling

CONTROLLING THE FIRE

Increase

Decrease

Secondary air pre-set slide

Thermostat Box

Wing nut

Thermostat

Knob

Thermostat rod
and connector

Fig. 3. Secondary air Adjustment

OPERATING  INSTRUCTIONS

®

charnwood

I S L A N D

5

Summary of Contents for Island III

Page 1: ...Operating Installation Instructions I S L A N D charnwood ...

Page 2: ......

Page 3: ...e flueway cleaning Chimney Sweeping Trouble Shooting If you need any Further Help Health Safety Precautions Chimney Hearth Fire Surround Connection to Flues Soot Doors Thermostat Dimensions 4 4 4 5 5 5 5 5 6 6 6 6 7 8 9 9 9 12 12 12 13 INSTALLATION INSTRUCTIONS Lighting Central Heating System System Controls Pre Lighting Check Commissioning Parts Lists Certification 4 10 11 12 12 14 15 I S L A N D...

Page 4: ... minimum effort If any operation such as riddling the grate or opening and closing the doors begins to require extra force then the cause must be investigated and corrected to prevent damage being caused to the stove Remember that the stove will be hot and is made from hard materials ensure that you have a good balance before operating the fire When using the stove in situations where children age...

Page 5: ...ct with the underside of the grate as this will seriously damage the grate bars The ashpan is handled using the tool provided Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins To make ash removal easier there is a special Charnwood ash carrier available This may be purchased from your supplier or in case of difficulty from ourselves For correct firing w...

Page 6: ... Cleaning Cleaning the Glass hob cleaner Some deposits on the glass may be burnt off simply by running the fire at a fast rate for a few minutes Do not use abrasive cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure Aerosol spray cleaners should not be used near the appliance whilst it is under fire If the fire is going to be out of use for a ...

Page 7: ...btained Keeping the glass clean requires a certain amount of experimentation due to the differences in the draw of different chimneys The following points should be noted and with a little care should enable the glass to be kept clean in most situations a The airwash relies on a supply of heated air to keep the glass clean therefore when lighting the stove allow the firebed to become well establis...

Page 8: ...hat it is not distorted c the door seals are in good condition d If the hot water goes cold when the pump is turned on or if some radiators are hotter than others then the system may need balancing the pump may be pumping the water too quickly around the system Fire blazing out of control Over Firing Freezing Lack of Heat To Radiators Hot Water or the radiators may need bleeding Please ask your in...

Page 9: ...he hearth must be at least 12mm 0 5inches thick The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances These building regulations state he chimney must not be less than 175 mm 7 inches internal diameter or 175 x 175mm internal square If an existing chimney is to be used it must be swept and checked it must be in good condition free from ...

Page 10: ...d corrosion a suitable inhibitor should be used The system must be correctly vented as shown in Figs 5 and 6 The height differential between the header tank and the appliance must not exceed 15 2 metres 50 feet If all four boiler tappings are used then if possible diagonal pairs should be connected for domestic hot water and central heating Where a common return is used an injector tee must be inc...

Page 11: ...Radiators may be either manually or thermostatically controlled These controls will all work in conjunction with the thermostat on the appliance and the low limit pipe thermostat We recommend fitting a pipe thermostat onto the gravity return to act as a low limit thermostat This should be wired into the mains supply to the pump so that if the gravity return temperature drops below 45º C then the p...

Page 12: ...MOSTAT With the control knob at the minimum setting the flap should be just closed as shown in Fig 13 To adjust the distance slacken the locking nut and adjust as necessary When set correctly re tighten the locking nut Ensure that the flap opens and closes freely as the knob is turned and that the opening is completely covered when the flap is closed Beforeinitiallightingthefollowingpoints shouldb...

Page 13: ...Flue Outlet To Suit 175mm 7 Flue Pipe 196 830 185 603 458 726 488 133 754 780 738 95 714 ISLAND IIIB DIMENSIONS charnwood I S L A N D 13 ...

Page 14: ...DS29S Set of Fire Bricks 4 14 008 FW48 Thermostat 15 010 DS31 Throat Plate 16 010 DS32 Front Throatplate 17 012 CY33 Mover Bar 18 002 CY30 Carrier Bar 19 012 AY13 Idler Rod 20 012 AY15 Riddler Rod 21 004 CY17L Ashpan L H 22 004 CY17R Ashpan R H 23 002 CY07C Front Fence Island 3 24 008 KV16 R H Door Handle 25 002 AY14 Door Catch Cam 26 008 KV13 L H Door Knob 27 008 BW39 S Hinge Pin Set 4 per set 28...

Page 15: ... WELLS SONS LTD EN13240 2001 ROOMHEATERS BOILER FIRED BY WOOD FUEL EC certificate of conformity no Maximum operating pressure Fuel types Minimum distance to combustible materials Side Rear Emission of CO in flue gases Flue gas temperature Space heating output Water heating output Energy efficiency DS50 CPD 2007 1 5 bar 200mm 120mm 0 67 354 C 9 0kW 9 0kW 73 3 Wood Logs ...

Page 16: ... i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 44 0 1983 537777 F 44 0 1983 537788 CHARNWOOD AJWELLS CO UK WWW CHARNWOOD COM charnwood y o u r p re m i e r d e a l e r REV ISLAND IIIB 03 09 ...

Reviews: