background image

* These items are not shown on the drawing.
# Please specify colour when ordering.

28

012/KW50/2

1

Airwash Slide R.H.

29

008/KW06

2

Airwash Control Knob

30

002/CG06

1

Riddler Knob

31

002/BW20

1

Riddler/Ashpan Tool

32

002/HW30F

1

Carrier Bar Front

33

002/HW30R

1

Carrier Bar Rear

34

012/HW33

1

Mover Bar

35

012/KW23

1

Riddler Rod

36

012/CG05

1

Idler Rod

37

003/KW11/#

1

Side Panel LH

38

003/KW12/#

1

Side Panel RH

39

003/KW13/#

1

Top Panel

40

003/KW01/#

1

Door

41

004/KW46

2

Fan Cover Plate

42

014/KW35

2

Fan

43

014/KW36

1

Fan Speed Control

44

008/KW37

1

Fan Speed Control Knob

45

014/KW38

1

Low Temperature Switch

46

014/KW49

1

Power Connection Socket

47

014/KW44

1

Power Supply (U.K.)

48

014/KW40

(1) Power Supply (European)

49

002/KW09

1

Flue collar

50

001/KW10

1

Firebox

51

001/KW05

1

Convection Casing

52

008/KW33

1

Door Catch Pin

53

008/FW33

1

Throat Plate Tool

54* 004/EW51

-

Ash Carrier (Optional Extra)

Nuts, bolts, screws and clips are
not shown for clarity.
To obtain spare parts contact your
local stockist giving model, part
no. and description.
In case of difficulty contact the
manufacturer at the address shown
below.
This drawing is for identification
purposes only.

1*

008/KW24

1

Door Seal

2*

008/FW29

-

Seal Adhesive

3*

008/KW25/S

(1) Glass Channel (set of 8)

4

006/KW20/A

2

Glass (Inc Channel)

5

004/KW19

4

Glass Retainer

6

001/KW07

1

Front Fire Bars

7

002/KW08

1

Throat Plate

8

011/KW29/B

2

Rear Fire Brick

9

011/KW29/L

2

Side Fire Brick

10

011/KW29/S

(1) Set of Bricks

11

012/KW32

1

Serial No. Label

12

002/KW15

2

Side Fire Plate

13

002/KW16

1

Back Fire Plate

14

002/CG01

7

Bottom Grate Bar

15

002/CG01/S7

(1) Set of Grate Bars

16

004/KW17

1

Ashpan (Open Ended)

17

004/KW17/C

(1) Ashpan (Closed End)

18

008/KW26/S

1

Hinge Pin Set

19

002/KW21

1

Door Catch

20

008/KW22

1

Door Handle

21

008/KW27

1

Door Catch Bracket

22

008/KW26

9

Roll Pin / Spacer

23

008/KW14

1

Primary Air Slide

24

004/KW18

2

Primary Air Slide Guide

25

008/KW47

1

Primary Air Control Knob

26

012/KW50/3

2

Airwash Control Rod

27

012/KW50/1

1

Airwash Slide L.H.

Bishops Way, Newport, Isle Of Wight, PO3O 5WS

Tel.(01983)527552 Fax.(01983)821267

Issue C 9/92

Item Part No.

Qty Description

Item Part No.

Qty Description

CHARNWOOD FIRECLASS PARTS LIST

Summary of Contents for FIRECLASS

Page 1: ...Bishops Way Newport Isle Of Wight PO3O 5WS Tel 01983 527552 Fax 01983 821267 CHARNWOOD FIRECLASS OPERATING AND INSTALLATION INSTRUCTIONS Page 1 Fireclass 0892 ...

Page 2: ... than 2 or 50 mm in size The coal should be dry When burning coal a little extra care is needed Please take note of the section Special Points For Burning Coal Wood Only dry well seasoned wood should be burnt on this appliance as burning wet unseasoned wood will give rise to heavy tar deposits For the same reason hard wood is better than soft wood Burning wet unseasoned wood will also result in co...

Page 3: ...Page 3 Fireclass 0892 ...

Page 4: ...ate as this will seriously damage the grate bars Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins Always close the door tightly after replacing the ashpan To make ash removal easier there is a special Charnwood ash carrier available This may be purchased from your supplier or in case of difficulty directly from ourselves RIDDLING When burning wood or p...

Page 5: ...Page 5 Fireclass 0892 ...

Page 6: ... be cleaned weekly The throat plate and flueways may be cleaned with a low fire still burning Lower the throat plate using the tool To do this engage the tool in the throat plate pull it forward and then lower it Use the tool to push any sooty deposits up the plate until they fall off the back and into the fire Return the throat plate to it s correct position as shown in Fig 3 raise the front of t...

Page 7: ...t occur However if a chimney fire does occur close both of the air controls and tightly close the door of the appliance This should cause the chimney fire to go out in which case the controls should be kept at the minimum setting until the stove has gone out The chimney and flueways should then be cleaned If the chimney fire does not go out when the above action is taken then the fire brigade shou...

Page 8: ...ee from cracks and blockages and should not have an excessive cross sectional area If you find that the chimney is in poor condition then expert advice should be sought regarding the necessity of having the chimney lined If it is found necessary to line the chimney then a lining suitable for Solid Fuel must be used If the appliance is to be fitted in a room where there is no existing chimney a pre...

Page 9: ...Page 9 Fireclass 0892 ...

Page 10: ... casing until the flue outlet lines up with the flue collar Working through the stove place the rope ring into the gap between the stove and the flue connection ring and then fit the bolts through the holes in the top of the stove and into the flue ring Apply a bead of fire cement to the gap between the flue ring and the stove and tighten the bolts Check that the flue pipe is not obstructed or res...

Page 11: ...Page 11 Fireclass 0892 ...

Page 12: ...ockist giving model part no and description In case of difficulty contact the manufacturer at the address shown below This drawing is for identification purposes only 1 008 KW24 1 Door Seal 2 008 FW29 Seal Adhesive 3 008 KW25 S 1 Glass Channel set of 8 4 006 KW20 A 2 Glass Inc Channel 5 004 KW19 4 Glass Retainer 6 001 KW07 1 Front Fire Bars 7 002 KW08 1 Throat Plate 8 011 KW29 B 2 Rear Fire Brick ...

Reviews: